Evidence map›Paper›PMID 38254818›Full record

ArticleCancers2024

The Role of Proton Therapy for Prostate Cancer in the Setting of Hip Prosthesis.

Maryam Moteabbed, Mislav Bobić, Harald Paganetti, Jason A Efstathiou

Open access · goldAbstract read
In one paragraph

Article in Cancers, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 2 countries.

Maryam MoteabbedDepartment of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Mislav BobićDepartment of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.ORCID 0000-0002-9409-8680
Harald PaganettiDepartment of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.ORCID 0000-0002-6257-2413
Jason A EfstathiouDepartment of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Harvard University · US

Funding

PROTON THERAPY RESEARCH AND TREATMENT CENTERC06CA059267 · NCI · MASSACHUSETTS GENERAL HOSPITAL · PI GOITEIN, MICHAEL · 1992 to 1995
–
NCI NIH HHS C06 CA059267
6 · The paper itself

Abstract

purposeGiven that the current standard of proton therapy (PT) for prostate cancer is through bilateral beams, this modality is typically avoided when it comes to treatment of patients with hip prosthesis. The purpose of this study was to evaluate whether novel PT methods, i.e., anterior proton beams and proton arc therapy (PArc), could be feasible options to treat this patient subpopulation. We evaluate PT methods in the context of dosimetry and robustness and compare with standard of practice volumetric modulated arc therapy (VMAT) to explore any potential benefits.

methodsTwo PT and one VMAT treatment plans were retrospectively created for 10 patients who participated in a clinical trial with a weekly repeat CT (rCT) imaging component. All plans were robustly optimized and featured: (1) combination anterior oblique and lateral proton beams (AoL), (2) PArc, and (3) VMAT. All patients had hydrogel spacers in place, which enabled safe application of anterior proton beams. The planned dose was 70 Gy (RBE) to the entire prostate gland and 50 Gy (RBE) to the proximal seminal vesicles in 28 fractions. Along with plan dose-volume metrics, robustness to setup and interfractional variations were evaluated using the weekly rCT images. The linear energy transfer (LET)-weighted dose was evaluated for PArc plans to ensure urethra sparing given the typical high-LET region at the end of range.

resultsBoth PT methods were dosimetrically feasible and provided reduction of some key OAR metrics compared to VMAT except for penile bulb, while providing equally good target coverage. Significant differences in median rectum V35 (22-25%), penile bulb Dmean (5 Gy), rectum V61 (2%), right femoral head Dmean (5 Gy), and bladder V39 (4%) were found between PT and VMAT. All plans were equally robust to variations. LET-weighted dose in urethra was equivalent to the physical dose for PArc plans and hence no added urethral toxicity was expected.

conclusionsPT for treatment of prostate cancer patients with hip prosthesis is feasible and equivalent or potentially superior to VMAT in quality in some cases. The choice of radiotherapy regimen can be personalized based on patient characteristics to achieve the best treatment outcome.

Indexed as

hip prosthesisprostate cancerproton arc therapy

Identifiers

PMID38254818
PMCPMC10813677
OpenAlexW4390754736

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.