Evidence map›Paper›PMID 38253772›Full record

ArticleScientific reports2024

Investigating the importance of left atrial compliance on fluid dynamics in a novel mock circulatory loop.

Masoud Meskin, Philip Alexander Starkey, Alexander Emil Kaspersen, Steffen Ringgaard, Signe Gram Sand, Jens Vinge Nygaard, Jørgen Arendt Jensen, Marie Sand Traberg, Peter Johansen

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
5.2field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Subtle echocardiographic markers of CAD: looking beyond the LV ejection fraction in stable angina patients.Clinical research in cardiology : official journal of the German Cardiac Society · 2025
    Article
  4. Article
  5. Technological evolution ofFrontiers in physiology · 2025
    Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Masoud MeskinCardiovascular Biomechanics Group, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark.
Philip Alexander StarkeyCardiovascular Experimental Laboratory, Department of Electrical and Computer Engineering, Aarhus University, Finlandsgade 22, 8200, Aarhus N, Denmark.
Alexander Emil KaspersenDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.
Steffen RinggaardMR Research Centre, Aarhus University, Aarhus, Denmark.
Signe Gram SandCardiovascular Experimental Laboratory, Department of Electrical and Computer Engineering, Aarhus University, Finlandsgade 22, 8200, Aarhus N, Denmark.
Jens Vinge NygaardBiomechanics and Mechanobiology, Department of Biological and Chemical Engineering, Aarhus University, Aarhus, Denmark.
Jørgen Arendt JensenCenter for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark.
Marie Sand TrabergCardiovascular Biomechanics Group, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark.
Peter JohansenCardiovascular Experimental Laboratory, Department of Electrical and Computer Engineering, Aarhus University, Finlandsgade 22, 8200, Aarhus N, Denmark. pj@ece.au.dk.
Aarhus University · DKTechnical University of Denmark · DKAarhus University Hospital · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The left atrium (LA) hemodynamic indices hold prognostic value in various cardiac diseases and disorders. To understand the mechanisms of these conditions and to assess the performance of cardiac devices and interventions, in vitro models can be used to replicate the complex physiological interplay between the pulmonary veins, LA, and left ventricle. In this study, a comprehensive and adaptable in vitro model was created. The model includes a flexible LA made from silicone and allows distinct control over the systolic and diastolic functions of both the LA and left ventricle. The LA was mechanically matched with porcine LAs through expansion tests. Fluid dynamic measures were validated against the literature and pulmonary venous flows recorded on five healthy individuals using magnetic resonance flow imaging. Furthermore, the fluid dynamic measures were also used to construct LA pressure-volume loops. The in vitro pressure and flow recordings expressed a high resemblance to physiological waveforms. By decreasing the compliance of the LA, the model behaved realistically, elevating the a- and v-wave peaks of the LA pressure from 12 to 19 mmHg and 22 to 26 mmHg, respectively, while reducing the S/D ratio of the pulmonary venous flowrate from 1.5 to 0.3. This model provides a realistic platform and framework for developing and evaluating left heart procedures and interventions.

Indexed as

Atrial AppendageHeart DiseasesAnimalsHeart AtriaHeart VentriclesHumansHydrodynamicsSwine

Identifiers

PMID38253772
PMCPMC10803730
OpenAlexW4391109982

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.