Evidence map›Paper›PMID 38253581›Full record

ArticleScientific reports2024

Self-filtering based on the fault ride-through technique using a robust model predictive control for wind turbine rotor current.

Abdelkader Achar, Youcef Djeriri, Habib Benbouhenni, Ilhami Colak, Mihai Oproescu, Nicu Bizon

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 9 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 3 countries.

Abdelkader AcharIntelligent Control and Electrical Power Systems Laboratory, Department of Electrotechnics, Faculty of Electrical Engineering, Djillali Liabes University, Sidi Bel-Abbes, Algeria. abdelkader.achar@univ-sba.dz.
Youcef DjeririIntelligent Control and Electrical Power Systems Laboratory, Department of Electrotechnics, Faculty of Electrical Engineering, Djillali Liabes University, Sidi Bel-Abbes, Algeria.
Habib BenbouhenniFaculty of Engineering and Architecture, Department of Electrical and Electronics Engineering, Nisantasi University, 34481742, Istanbul, Turkey.
Ilhami ColakFaculty of Engineering and Architecture, Department of Electrical and Electronics Engineering, Nisantasi University, 34481742, Istanbul, Turkey.
Mihai OproescuThe National University of Science and Technology POLITEHNICA Bucharest, Pitești University Centre, 110040, Pitesti, Romania.
Nicu BizonThe National University of Science and Technology POLITEHNICA Bucharest, Pitești University Centre, 110040, Pitesti, Romania.
İstanbul Nişantaşı Üniversitesi · TRUniversité Djilali de Sidi Bel Abbès · DZUniversity of Bucharest · ROUniversity of Pitesti · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper studies the possibility of connecting Wind Farms (WF) to the electric grid with the use of finite space model predictive command (FS-MPC) to manage wind farms to improve the quality of the current output from the doubly-fed induction generator (DFIG) with considering fault ride-through technique. This proposed system can generate active power and enhance the power factor. Furthermore, the reduction of harmonics resulting from the connection of non-linear loads to the electrical grid is achieved through the self-active filtering mechanism in DFIGs-WF, facilitated by the now algorithm proposed. FS-MPC technique has the ability to improve system characteristics and greatly reduce active power ripples. Therefore, MATLAB software is used to implement and verify the safety, performance, and effectiveness of this designed technique compared to the conventional strategy. The results obtained demonstrated the effectiveness of the proposed algorithm in handling the four operational modes (Maximum power point tracking, Delta, Fault, and Filtering). Additionally, the suggested technique exhibited flexibility, robustness, high accuracy, and fast dynamic response when compared to conventional strategies and some recently published scientific works. On the other hand, the THD value of the current was significantly reduced, obtaining at one test time the values 56.87% and 0.32% before and after filtering, respectively 27.50% and 0.26% at another time of testing, resulting in an estimated THD reduction percentage of 99.43% and 99.05%, respectively. These high percentages prove that the quality of the stream is excellent after applying the proposed strategy.

Identifiers

PMID38253581
PMCPMC11226680
OpenAlexW4391103310

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.