ArticleBiomimetics (Basel, Switzerland)2023
Bionic Design and Optimization on the Flow Channel of a Legged Robot Joint Hydraulic Drive Unit Based on Additive Manufacturing.
Article in Biomimetics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Design and Position Control of a Bionic Joint Actuated by Shape Memory Alloy Wires.Biomimetics (Basel, Switzerland) · 2024Article
- Multi-Modal Enhancement Transformer Network for Skeleton-Based Human Interaction Recognition.Biomimetics (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
The joint hydraulic drive unit (HDU) serves as a pivotal element in enabling the high-performance movements of legged robots. Functioning as the conduit linking the oil source and the actuator, the hydraulic flow channel significantly impacts actuator performance. Hence, optimizing the HDU flow channel becomes imperative, enhancing not only HDU efficiency but also the overall system performance. This paper introduces a novel approach by aligning the hydraulic flow channel of the joint HDU with the arteriovenous layout of the cardiac vascular system, departing from the conventional machining flow channel model. Through simulations determining the optimal range of the vascular branch radius and angle, this study guides the design optimization of the joint HDU flow channel. With the primary optimization goal of reducing pressure loss, the study compares simulation outcomes of various flow channel models-linear, variable excessive radius, and the multidimensional Bessel curve-tailored to suit the arrangement specifics of the joint HDU. Further validating these designs, the flow channels are fabricated using additive manufacturing for experimental verification. The integration of simulation analyses and pressure loss testing reveals a remarkable reduction of over 40% in pressure loss for the bionic flow channel compared to the conventional machining form. This empirical evidence strongly substantiates the bionic flow channel's superior efficacy in pressure loss reduction. The findings presented herein offer valuable insights for the development of low-loss flow channels in joint HDUs, thereby presenting a new avenue for designing energy-efficient, high power-to-weight ratio legged robots.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.