Evidence map›Paper›PMID 38248407›Full record

ArticleBiosensors2024

The Quantitative Detection of Cystatin-C in Patient Samples Using a Colorimetric Lateral Flow Immunoassay.

Santosh Kumar Bikkarolla, Kavipriya Venkatesan, Yeddula Rebecca Revathy, Sowmya Parameswaran, Subramanian Krishnakumar, Dhananjaya Dendukuri

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
4.9field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Santosh Kumar BikkarollaAchira Labs, 66b, 13th Cross Rd, Dollar Layout, 3rd Phase, J. P. Nagar, Bengaluru 560078, India.
Kavipriya VenkatesanAchira Labs, 66b, 13th Cross Rd, Dollar Layout, 3rd Phase, J. P. Nagar, Bengaluru 560078, India.
Yeddula Rebecca RevathyVision Research Foundation, Chennai 600006, India.
Sowmya ParameswaranVision Research Foundation, Chennai 600006, India.ORCID 0000-0002-2508-0743
Subramanian KrishnakumarVision Research Foundation, Chennai 600006, India.ORCID 0000-0002-1958-5999
Dhananjaya DendukuriAchira Labs, 66b, 13th Cross Rd, Dollar Layout, 3rd Phase, J. P. Nagar, Bengaluru 560078, India.

Funding

Achira Labs Not applicableCipla (India) Not applicable
6 · The paper itself

Abstract

A colloidal gold-based lateral flow immunoassay was developed for the rapid quantitative detection of Cystatin-C in serum and whole blood. This device has an assay time of 15 min, making it a convenient point-of-care diagnostic tool. The device has a quantification range spanning from 0.5 to 7.5 µg/mL, with a lower limit of detection at 0.18 µg/mL. To validate its accuracy, the test was compared to a standard nephelometric immunoassay, and the results exhibited a robust linear correlation with an adjusted r

Indexed as

Biological AssayColorimetryHumansImmunoassayPoint-of-Care SystemsCystatin-Cgold nanoparticleslateral flow immunoassaypatient-whole bloodserum-samples

Identifiers

PMID38248407
PMCPMC10813198
OpenAlexW4390722330

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.