Evidence map›Paper›PMID 38248391›Full record

ArticleBiosensors2023

An Analysis of Fluid Intake Assessment Approaches for Fluid Intake Monitoring System.

Chia-Yeh Hsieh, Hsiang-Yun Huang, Chia-Tai Chan, Li-Tzu Chiu

Abstract read
In one paragraph

Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chia-Yeh HsiehBachelor's Program in Medical Informatics and Innovative Applications, Fu Jen Catholic University, New Taipei City 24205, Taiwan.ORCID 0000-0002-6771-2067
Hsiang-Yun HuangDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei City 11221, Taiwan.ORCID 0000-0002-2319-1204
Chia-Tai ChanDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei City 11221, Taiwan.ORCID 0000-0003-0995-601X
Li-Tzu ChiuDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei City 11221, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Monitoring fluid intake is essential to help people manage their individual fluid intake behaviors and achieve adequate hydration. Previous studies of fluid intake assessment approaches based on inertial sensors can be categorized into wrist-worn-based and smart-container-based approaches. This study aims to analyze wrist-worn-based and smart-container-based fluid intake assessment approaches using inertial sensors. The comparison of these two approaches should be analyzed according to gesture recognition and volume estimation. In addition, the influence of the fill level and sip size information on the performance is explored in this study. The accuracy of gesture recognition with postprocessing is 92.89% and 91.8% for the wrist-worn-based approach and smart-container-based approach, respectively. For volume estimation, sip-size-dependent models can achieve better performance than general SVR models for both wrist-worn-based and smart-container-based approaches. The improvement of MAPE, MAD, and RMSE can reach over 50% except MAPE for small sip sizes. The results demonstrate that the sip size information and recognition performance are important for fluid intake assessment approaches.

Indexed as

DrinkingHumansWearable Electronic DevicesWristfluid intake assessmentgesture recognitionsmart-container sensorvolume estimationwrist-worn sensor

Identifiers

PMID38248391
PMCPMC10813732

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.