ArticleBioengineering (Basel, Switzerland)2024
Flow Diverter Performance Comparison of Different Wire Materials for Effective Intracranial Aneurysm Treatment.
Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 10 citations in OpenAlex.
- FloWise Flow Diverter for Treatment of Unruptured Wide-Neck Intracranial Aneurysms: A Prospective, Multicenter, Single-Arm, Open-Label, Pivotal Study.Korean journal of radiology · 2025Trial
- Defining biomaterial-driven design principles for bioabsorbable flow diverters: current state and perspectives.Bioactive materials · 2027Review
- Outcomes, complications, and management in flow diverter treatment of cerebral aneurysms: a 15-year single-center experience.Neuroradiology · 2026Article
- Single-layer spherical (SLS) vs single-layer (SL) Woven EndoBridge (WEB) device in the treatment of narrow-neck intracranial aneurysms: a propensity score-matched analysis.Neurosurgical review · 2026Article
- Optimization of braided stent design for cerebral aneurysms: the role of wire cross-sectional geometry.Frontiers in bioengineering and biotechnology · 2025Article
- Efficacy and safety of flow diverters in basilar artery aneurysms: a single-center retrospective cohort study.Frontiers in neurology · 2025Article
- Case Report: Application of the LVIS stent as a bridging device for salvage treatment of malapposed lattice flow diverter in a giant posterior circulation aneurysm: technical note and clinical efficacy.Frontiers in surgery · 2025Article
- Comparison of Pipeline embolization device versus Tubridge embolization device in unruptured intracranial aneurysms: a multicenter, propensity score matched study.Journal of neurointerventional surgery · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
Abstract
A flow diverter (FD) is an effective method for treating wide-necked intracranial aneurysms by inducing hemodynamic changes in aneurysms. However, the procedural technique remains challenging, and it is often not performed properly in many cases of deployment or placements. In this study, three types of FDs that changed the material of the wire were prepared within the same structure. Differences in physical properties, such as before and after delivery loading stent size, radial force, and radiopacity, were evaluated. The performances in terms of deployment and trackability force were also evaluated in a simulated model using these FDs. Furthermore, changes of deployment patterns when these FDs were applied to a 3D-printed aneurysm model were determined. The NiTi FD using only nitinol (NiTi) wire showed 100% size recovery and 42% to 45% metal coverage after loading. The low trackability force (10.9 to 22.9 gf) allows smooth movement within the delivery system. However, NiTi FD cannot be used in actual surgeries due to difficulties in X-ray identification. NiTi-Pt/W FD, a combination of NiTi wire and platinum/tungsten (Pt/W) wire, had the highest radiopacity and compression force (6.03 ± 0.29 gf) among the three FDs. However, it suffered from high trackability force (22.4 to 39.9 gf) and the end part braiding mesh tended to loosen easily, so the procedure became more challenging. The NiTi(Pt) FD using a platinum core nitinol (NiTi(Pt)) wire had similar trackability force (11.3 to 22.1 gf) to NiTi FD and uniform deployment, enhancing procedural convenience. However, concerns about low expansion force (1.79 ± 0.30 gf) and the potential for migration remained. This comparative analysis contributes to a comprehensive understanding of how different wire materials influence the performance of FDs. While this study is still in its early stages and requires further research, its development has the potential to guide clinicians and researchers in optimizing the selection and development of FDs for the effective treatment of intracranial aneurysms.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.