Evidence map›Paper›PMID 38246928›Full record

ArticleScientific reports2024

Effect of longer femoral head on leg length, offset, and range of motion in total hip arthroplasty: a simulation study.

Tomohiro Shimizu, Takuji Miyazaki, Shunichi Yokota, Hotaka Ishizu, Daisuke Takahashi, Norimasa Iwasaki

Erratum issuedAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Does glenosphere size impact shoulder rotational range of motion after reverse shoulder arthroplasty? A retrospective cohort study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Tomohiro Shimizu *Department of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-15, Nish-7, Kita-ku, Sapporo, 060-8638, Japan. simitom@wg8.so-net.ne.jp.
Takuji Miyazaki *Department of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-15, Nish-7, Kita-ku, Sapporo, 060-8638, Japan.
Shunichi YokotaDepartment of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-15, Nish-7, Kita-ku, Sapporo, 060-8638, Japan.
Hotaka IshizuDepartment of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-15, Nish-7, Kita-ku, Sapporo, 060-8638, Japan.
Daisuke TakahashiDepartment of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-15, Nish-7, Kita-ku, Sapporo, 060-8638, Japan.
Norimasa IwasakiDepartment of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-15, Nish-7, Kita-ku, Sapporo, 060-8638, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, we investigated the relationship between head length, leg length, offset, and dislocation resistance using range of motion (ROM) simulations based on computed tomography data to examine if a longer femoral head reduces the risk of dislocation. The femoral components were set to eliminate leg length differences with a + 0 mm head, and variations for + 4-, + 7-, and + 8-mm heads were analyzed. Offset and ROM were assessed when longer heads were used, with the leg length adjusted to be similar to that of the contralateral side. While internal rotation at flexion and external rotation at extension increased with + 4-mm longer heads, the + 7- and + 8-mm heads did not increase dislocation resistance. When adjusting for leg length, the longer heads showed no significant differences in offset and ROM. Enhancing dislocation resistance by solely increasing the offset with a longer head, while simultaneously adjusting the depth of stem insertion, may be a beneficial intraoperative technique. Although a + 4-mm longer head possibly increases ROM without impingement, heads extended by + 7 or + 8 mm may not exhibit the same advantage. Therefore, surgeons should consider this technique based on the implant design.

Indexed as

Arthroplasty, Replacement, HipJoint DislocationsComputer SimulationFemur HeadHumansRange of Motion, Articular

Identifiers

PMID38246928
PMCPMC10800334

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.