Evidence map›Paper›PMID 38240181›Full record

ArticleACS applied materials & interfaces2024

Safe and Efficacious Near Superhydrophobic Hemostat for Reduced Blood Loss and Easy Detachment in Traumatic Wounds.

Yibing Dong, Yaoxian Xu, Chengxing Lian, Krisna Prak, Hwa Liang Leo, Teresa D Tetley, Vania Braga, Mike Emerson, Josefin Ahnström, Choon Hwai Yap

Open access · hybridAbstract read
In one paragraph

Article in ACS applied materials & interfaces, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
7.3field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Yibing DongDepartment of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore.
Yaoxian XuDepartment of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom.
Chengxing LianDepartment of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom.
Krisna PrakNational Heart and Lung Institute, Imperial College London, London SW3 6LY, United Kingdom.
Hwa Liang LeoDepartment of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore.
Teresa D TetleyNational Heart and Lung Institute, Imperial College London, London SW3 6LY, United Kingdom.
Vania BragaNational Heart and Lung Institute, Imperial College London, London SW3 6LY, United Kingdom.
Mike EmersonNational Heart and Lung Institute, Imperial College London, London SW3 6LY, United Kingdom.
Josefin AhnströmDepartment of Immunology and Inflammation, Imperial College London, London W12 0NN, United Kingdom.
Choon Hwai YapDepartment of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom.ORCID 0000-0003-2918-3077
Imperial College London · GBNational University of Singapore · SG

Funding

Medical Research Council MC_PC_19040
6 · The paper itself

Abstract

Hemorrhage is the leading cause of trauma death, and innovation in hemostatic technology is important. The strongly hydrophobic carbon nanofiber (CNF) coating has previously been shown to have excellent hemostatic properties. However, the understanding of how CNF coating guides the coagulation cascade and the biosafety of CNF as hemostatic agents has yet to be explored. Here, our thrombin generation assay investigation showed that CNF induced fast blood coagulation via factor (F) XII activation of the intrinsic pathway. We further performed studies of a rat vein injury and demonstrated that the CNF gauze enabled a substantial reduction of blood loss compared to both the plain gauze and kaolin-imbued gauze (QuikClot). Analysis of blood samples from the model revealed no acute toxicity from the CNF gauze, with no detectable CNF deposition in any organ, suggesting that the immobilization of CNF on our gauze prevented the infiltration of CNF into the bloodstream. Direct injection of CNF into the rat vein was also investigated and found not to elicit overt acute toxicity or affect animal survival or behavior. Finally, toxicity assays with primary keratinocytes revealed minimal toxicity responses to CNF. Our studies thus supported the safety and efficacy of the CNF hemostatic gauze, highlighting its potential as a promising approach in the field of hemostatic control.

Indexed as

HemorrhageHemostaticsAnimalsBlood CoagulationDisease Models, AnimalHemostasisHydrophobic and Hydrophilic InteractionsRatsHemostaticsbandageblood coagulation pathwaycarbon nanofiberhemostasissuperhydrophobictoxicitytrauma

Identifiers

PMID38240181
PMCPMC10835652
OpenAlexW4391027982

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.