Evidence map›Paper›PMID 38239876›Full record

ArticleFrontiers in cardiovascular medicine2023

Local impedance and contact force guidance to predict successful cavotricuspid isthmus ablation with a zero-fluoroscopy approach.

Jorge Melero-Polo, Mercedes Cabrera-Ramos, Jose Manuel Alfonso-Almazán, Isabel Marín-García, Isabel Montilla-Padilla, José Ramón Ruiz-Arroyo, Guillermo López-Rodríguez, Javier Ramos-Maqueda

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jorge Melero-PoloArrhythmias Unit, Department of Cardiology, Aragón Health Research Institute, University Hospital Clínico Lozano Blesa, Zaragoza, Spain.
Mercedes Cabrera-RamosArrhythmias Unit, Department of Cardiology, Aragón Health Research Institute, University Hospital Clínico Lozano Blesa, Zaragoza, Spain.
Jose Manuel Alfonso-AlmazánMaster of Science, Boston Scientific, Madrid, Spain.
Isabel Marín-GarcíaMaster of Science, Boston Scientific, Madrid, Spain.
Isabel Montilla-PadillaArrhythmias Unit, Department of Cardiology, Aragón Health Research Institute, University Hospital Clínico Lozano Blesa, Zaragoza, Spain.
José Ramón Ruiz-ArroyoArrhythmias Unit, Department of Cardiology, Aragón Health Research Institute, University Hospital Clínico Lozano Blesa, Zaragoza, Spain.
Guillermo López-RodríguezMaster of Science, Boston Scientific, Madrid, Spain.
Javier Ramos-MaquedaArrhythmias Unit, Department of Cardiology, Aragón Health Research Institute, University Hospital Clínico Lozano Blesa, Zaragoza, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: A new technology capable of monitoring local impedance (LI) and contact force (CF) has recently been developed. At the same time, there is growing concern regarding catheter ablation performed under fluoroscopy guidance, due to its harmful effects for both patients and practitioners. The aim of this study was to assess the safety and effectiveness of zero-fluoroscopy cavotricuspid isthmus (CTI) ablation monitoring LI drop and CF as well as to elucidate if these parameters can predict successful radiofrequency (RF) applications in CTI ablation. Methods: We conducted a prospective observational study recruiting 50 consecutive patients who underwent CTI ablation. A zero-fluoroscopy approach guided by the combination of LI drop and CF was performed. In each RF application, CF and LI drop were monitored. A 6-month follow-up visit was scheduled to assess recurrences. Results: A total of 767 first-pass RF applications were evaluated in 50 patients. First-pass effective RF applications were associated with greater LI drops: absolute LI drops (30.05 ± 6.23 Ω vs. 25.01 ± 5.95 Ω), Conclusions: LI drop (absolute and relative values) appears to be a good predictor of successful RF applications to achieve CTI conduction block. The optimal CF to achieve a good LI drop is between 5 and 15 g. A zero-fluoroscopy approach guided by LI and CF was feasible, effective, and safe.

Indexed as

catheter ablationcavotricuspid isthmuscontact forcelocal impedancezero-fluoroscopy

Identifiers

PMID38239876
PMCPMC10794657

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.