Evidence map›Paper›PMID 38238358›Full record

ArticleScientific reports2024

In vitro investigation of the blood flow downstream of a 3D-printed aortic valve.

Till Zeugin, Fergal B Coulter, Utku Gülan, André R Studart, Markus Holzner

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Till ZeuginDepartment of Civil, Environmental and Geomatic Engineering, Institute of Environmental Engineering, Swiss Federal Institute of Technology ETH Zürich, Zürich, Switzerland. zeugin@ifu.baug.ethz.ch.ORCID http://orcid.org/0000-0002-3327-7802
Fergal B CoulterComplex Materials, Swiss Federal Institute of Technology ETH Zürich, Zürich, Switzerland.
Utku GülanHi-D Imaging, Winterthur, Switzerland.
André R StudartComplex Materials, Swiss Federal Institute of Technology ETH Zürich, Zürich, Switzerland.ORCID http://orcid.org/0000-0003-4205-8545
Markus HolznerSwiss Federal Institute for Forest, Snow and Landscape Research WSL, Birmensdorf, Switzerland.

Funding

Schweizerischer Nationalfonds zur F &;#x00F6;rderung der Wissenschaftlichen Forschung (Swiss National Science Foundation) 191987
6 · The paper itself

Abstract

The hemodynamics in the aorta as well as the durability of aortic valve prostheses vary greatly between different types of devices. Although placement and sizing of surgical aortic valve prostheses are excellent, the valve geometry of common devices cannot be customized to fit the patient's anatomy perfectly. Similarly, transcatheter aortic valve implantation (TAVI) devices are not customizable and may be orientated unfavorably during implantation. Imperfect fit of an aortic valve prosthesis may result in suboptimal performance and in some cases the need for additional surgery. Leveraging the advent of precision, multi-material 3D-printing, a bioinspired silicone aortic valve was developed. The manufacturing technique makes it fully customizable and significantly cheaper to develop and produce than common prostheses. In this study, we assess the hemodynamic performance of such a 3D-printed aortic valve and compare it to two TAVI devices as well as to a severely stenosed valve. We investigate the blood flow distal to the valve in an anatomically accurate, compliant aorta model via three-dimensional particle tracking velocimetry measurements. Our results demonstrate that the 3D-printed aortic valve induces flow patterns and topology compatible with the TAVI valves and showing similarity to healthy aortic blood flow. Compared to the stenosis, the 3D-printed aortic valve reduces turbulent kinetic energy levels and irreversible energy losses by over 75%, reaching values compatible with healthy subjects and conventional TAVIs. Our study substantiates that the 3D-printed heart valve displays a hemodynamic performance similar to established devices and underscores its potential for driving innovation towards patient specific valve prostheses.

Indexed as

Aortic Valve StenosisTranscatheter Aortic Valve ReplacementAortic ValveHemodynamicsHumansPrinting, Three-DimensionalProsthesis DesignTreatment Outcome

Identifiers

PMID38238358
PMCPMC10796383

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.