Clinical evaluation of a fully electronic microfluidic white blood cell analyzer.

Jianye Sui, Zhongtian Lin, Shahriar Azizpour, Fei Chen, Sunanda Gaur, Kelly Keene, Farzad Soleimani, Tanaya Bhowmick, Zubaid Rafique, Mehdi Javanmard

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Diagnostic accuracy of CardiochekLipids in health and disease · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jianye SuiRizLab Health, Inc., Princeton, New Jersey, United States of America.
Zhongtian LinRizLab Health, Inc., Princeton, New Jersey, United States of America.
Shahriar AzizpourRizLab Health, Inc., Princeton, New Jersey, United States of America.
Fei ChenDepartment of Pediatrics, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, United States of America.
Sunanda GaurDepartment of Pediatrics, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, United States of America.
Kelly KeeneDepartment of Emergency Medicine, Baylor College of Medicine, Houston, Texas, United States of America.
Farzad SoleimaniDepartment of Emergency Medicine, Baylor College of Medicine, Houston, Texas, United States of America.
Tanaya BhowmickDepartment of Medicine, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, United States of America.
Zubaid RafiqueDepartment of Emergency Medicine, Baylor College of Medicine, Houston, Texas, United States of America.
Mehdi JavanmardRizLab Health, Inc., Princeton, New Jersey, United States of America.ORCID 0000-0002-6297-392X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The White Blood Cell (WBC) count is one of the key parameters signaling the health of the immune system. Abnormal WBC counts often signal a systemic insult to the body such as an underlying infection or an adverse side effect to medication. Typically, the blood collected is sent to a central lab for testing, and results come back within hours, which is often inconvenient and may delay time-sensitive diagnosis or treatment. Here, we present the CytoTracker, a fully electronic, microfluidic based instant WBC analyzer with the potential to be used at point-of-care. The CytoTracker is a lightweight, portable, affordable platform capable of quantifying WBCs within minutes using only 50 μl of blood (approximately one drop of blood). In this study, we clinically evaluated the accuracy and performance of CytoTracker in measuring WBC and granulocyte counts. A total of 210 adult patients were recruited in the study. We validated the CytoTracker against a standard benchtop analyzer (Horiba Point of Care Hematology Analyzer, ABX Micros 60). Linear dynamic ranges of 2.5 k/μl- 35 k/μl and 0.6 k/μl- 26 k/μl were achieved for total WBC count and granulocyte count with correlation coefficients of 0.97 and 0.98. In addition, we verified CytoTracker's capability of identifying abnormal blood counts with above 90% sensitivity and specificity. The promising results of this clinical validation study demonstrate the potential for the use of the CytoTracker as a reliable and accurate point-of-care WBC analyzer.

Indexed as

HematologyMicrofluidicsAdultBlood Cell CountHumansLeukocyte CountLeukocytes

Identifiers

PMID38236796
PMCPMC10796056

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.