Evidence map›Paper›PMID 38235952›Full record

ArticleJournal of applied clinical medical physics2024

Four-dimensional treatment planning strategies for dynamic tumor tracking.

Emilie E Carpentier, Ronan L McDermott, Marie-Laure A Camborde, Tania Karan, Alanah M Bergman, Ante Mestrovic

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Four-dimensional treatment planning strategies for dynamic tumor tracking.Journal of applied clinical medical physics · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Emilie E CarpentierDepartment of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.
Ronan L McDermottRadiation Oncology, BC Cancer Vancouver, Vancouver, British Columbia, Canada.
Marie-Laure A CambordeDepartment of Medical Physics, BC Cancer - Vancouver, Vancouver, British Columbia, Canada.
Tania KaranDepartment of Medical Physics, BC Cancer - Vancouver, Vancouver, British Columbia, Canada.ORCID https://orcid.org/0000-0002-9243-9672
Alanah M BergmanDepartment of Medical Physics, BC Cancer - Vancouver, Vancouver, British Columbia, Canada.ORCID https://orcid.org/0000-0003-0546-7681
Ante MestrovicDepartment of Medical Physics, BC Cancer - Vancouver, Vancouver, British Columbia, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDynamic tumor tracking (DTT) is a motion management technique where the radiation beam follows a moving tumor in real time. Not modelling DTT beam motion in the treatment planning system leaves an organ at risk (OAR) vulnerable to exceeding its dose limit. This work investigates two planning strategies for DTT plans, the "Boolean OAR Method" and the "Aperture Sorting Method," to determine if they can successfully spare an OAR while maintaining sufficient target coverage. MATERIALS AND

methodsA step-and-shoot intensity modulated radiation therapy (sIMRT) treatment plan was re-optimized for 10 previously treated liver stereotactic ablative radiotherapy patients who each had one OAR very close to the target. Two planning strategies were investigated to determine which is more effective at sparing an OAR while maintaining target coverage: (1) the "Boolean OAR Method" created a union of an OAR's contours from two breathing phases (exhale and inhale) on the exhale phase (the planning CT) and protected this combined OAR during plan optimization, (2) the "Aperture Sorting Method" assigned apertures to the breathing phase where they contributed the least to an OAR's maximum dose.

resultsAll 10 OARs exceeded their dose constraints on the original plan four-dimensional (4D) dose distributions and average target coverage was V

conclusions4D planning strategies are simple to implement and can improve OAR sparing during DTT treatments. The "Boolean OAR Method" improved sparing of OARs but target coverage was reduced. The "Aperture Sorting Method" further improved sparing of OARs and maintained target coverage.

Indexed as

Organs at RiskRadiosurgeryRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedAlgorithmsFour-Dimensional Computed TomographyHumansLiver NeoplasmsMovementRespiration4D dose calculation4D treatment planningdynamic tumor trackinggimballed linac system

Identifiers

PMID38235952
PMCPMC11163504

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.