Evidence map›Paper›PMID 38233950›Full record

ArticleJournal of orthopaedic surgery and research2024

Comparative study of locking neutralization plate construct versus tension band wiring with a cannulated screw for patella fractures: experimental and finite element analysis.

Sunjung Kim, Nirav Mungalpara, Rohan Wangikar, Majd Tarabichi, Joseph Karam, Asheesh Bedi, Jason Koh, Farid Amirouche

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
4.0field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Sunjung KimDepartment of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Nirav MungalparaDepartment of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Rohan WangikarDepartment of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Majd TarabichiDepartment of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Joseph KaramDepartment of Orthopedic Surgery, Orthopedic and Spine Institute, Northshore University Health System, An Affiliate of the University of Chicago Pritzker School of Medicine, 9669 Kenton Avenue, Skokie, IL, 60076, USA.
Asheesh BediDepartment of Orthopedic Surgery, Orthopedic and Spine Institute, Northshore University Health System, An Affiliate of the University of Chicago Pritzker School of Medicine, 9669 Kenton Avenue, Skokie, IL, 60076, USA.
Jason KohDepartment of Orthopedic Surgery, Orthopedic and Spine Institute, Northshore University Health System, An Affiliate of the University of Chicago Pritzker School of Medicine, 9669 Kenton Avenue, Skokie, IL, 60076, USA.
Farid AmiroucheDepartment of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA. famirouche@northshore.org.
University of Illinois Chicago · USUniversity of Chicago · USNorthShore University HealthSystem · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transverse patella fractures, accounting for approximately 1% of Orthopedic injuries, pose intricate challenges due to their vital role in knee mechanics. This study aimed to compare the biomechanical performance of a construct, integrating cannulated screws and an anterior locking neutralization plate, with the conventional tension band wiring technique for treating these fractures. Experimental testing and Finite Element Analysis were employed to evaluate the constructs and gain profound insights into their mechanical behavior. Sixteen cadaveric knees were prepared, and transverse patella fractures were induced at the midpoints using a saw. The plate construct and tension band wire fixation were randomly assigned to the specimens. A cyclic test evaluated the implants' durability and stability, simulating knee movement during extension and flexion. Tensile testing assessed the implants' maximum failure force after cyclic testing, while Finite Element Analysis provided detailed insights into stress distribution and deformation patterns. Statistical analysis was exclusively performed for the experimental data. Results showed the plate enhanced stability with significantly lower deformation (0.09 ± 0.12 mm) compared to wire fixation (0.77 ± 0.54 mm) after 500 cycles (p = 0.004). In tensile testing, the construct also demonstrated higher failure resistance (1359 ± 21.53 N) than wire fixation (780.1 ± 22.62N) (p = 0.007). Finite Element Analysis highlighted distinct stress patterns, validating the construct's superiority. This research presents a promising treatment approach for transverse patella fractures with potential clinical impact and future research prospects. This study presents a promising advancement in addressing the intricate challenges of transverse patella fractures, with implications for refining clinical practice. The construct's improved stability and resistance to failure offer potential benefits in postoperative management and patient outcomes.

Indexed as

Fractures, BoneKnee InjuriesPatella FractureBiomechanical PhenomenaBone ScrewsBone WiresCadaverFinite Element AnalysisFracture Fixation, InternalHumansPatella

Identifiers

PMID38233950
PMCPMC10795423
OpenAlexW4390984055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.