Evidence map›Paper›PMID 38233794›Full record

ArticleBMC oral health2024

Evaluation of micromotion in multirooted root analogue implants embedded in synthetic bone blocks: an in vitro study.

Mostafa Aldesoki, Christoph Bourauel, Tarek M Elshazly, Erik Schkommodau, Ludger Keilig

Open access · goldAbstract read
In one paragraph

Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.5field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Mostafa AldesokiDental School, Oral Technology, University Hospital Bonn, Welschnonnenstr.17, 53111, Bonn, Germany. mostafadesoki86@gmail.com.ORCID 0000-0002-3799-0496
Christoph BourauelDental School, Oral Technology, University Hospital Bonn, Welschnonnenstr.17, 53111, Bonn, Germany.
Tarek M ElshazlyDental School, Oral Technology, University Hospital Bonn, Welschnonnenstr.17, 53111, Bonn, Germany.
Erik SchkommodauInstitute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland.
Ludger KeiligDental School, Oral Technology, University Hospital Bonn, Welschnonnenstr.17, 53111, Bonn, Germany.
University Hospital Bonn · DEFHNW University of Applied Sciences and Arts · CH

Funding

Deutscher Akademischer Austauschdienst DAAD, 2019/20, 57440921
6 · The paper itself

Abstract

backgroundWhile conventional threaded implants (TI) have proven to be effective for replacing missing teeth, they have certain limitations in terms of diameter, length, and emergence profile when compared to customised root analogue implants (RAI). To further investigate the potential benefits of RAIs, the aim of this study was to experimentally evaluate the micromotion of RAIs compared to TIs.

methodsA 3D model of tooth 47 (mandibular right second molar) was segmented from an existing cone beam computed tomography (CBCT), and a RAI was designed based on this model. Four RAI subgroups were fabricated as follows: 3D-printed titanium (PT), 3D-printed zirconia (PZ), milled titanium (MT), milled zirconia (MZ), each with a sample size of n = 5. Additionally, two TI subgroups (B11 and C11) were used as control, each with a sample size of n = 5. All samples were embedded in polyurethane foam artificial bone blocks and subjected to load application using a self-developed biomechanical Hexapod Measurement System. Micromotion was quantified by analysing the load/displacement curves.

resultsThere were no statistically significant differences in displacement in Z-axis (the loading direction) between the RAI group and the TI group. However, within the RAI subgroups, PZ exhibited significantly higher displacement values compared to the other subgroups (p < 0.05). In terms of the overall total displacement, the RAI group showed a statistically significant higher displacement than the TI group, with mean displacement values of 96.5 µm and 55.8 µm for the RAI and TI groups, respectively.

conclusionsThe RAI demonstrated promising biomechanical behaviour, with micromotion values falling within the physiological limits. However, their performance is less predictable due to varying anatomical designs.

Indexed as

Dental ImplantsHumansSoftwareTitaniumZirconiumDental ImplantsTitaniumZirconiumzirconium oxide3D printingBiomechanicsDental implantsMillingMotionPatient specificStabilityTitaniumZirconia

Identifiers

PMID38233794
PMCPMC10792929
OpenAlexW4390947811

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.