ArticlePolymers2023
Study on Self-Humidification in PEMFC with Crossed Flow Channels and an Ultra-Thin Membrane.
Article in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 10 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this study, a 3D model of a proton exchange membrane fuel cell (PEMFC) with crossed channels and an ultra-thin membrane is developed to investigate the feasibility of self-humidification; experiments utilizing a PEMFC stack with identical configurations are conducted to validate the simulation results and further investigate the effects of various operating conditions (OCs) on self-humidification. The results indicate that the crossed flow channel leads to enhanced uniformity of water distribution, resulting in improved cell performance under low/no humidification conditions. External humidifiers for the anode can be removed since the performance difference is negligible (≤3%) between RHa = 0% and 100%. Self-humidification can be achieved in the stack at 90 °C or below with an appropriate back pressure among 100-200 kPa. As the current density increases, there is a gradual convergence and crossing of the voltage at low RH with that at high RH, and the crossover points are observed at 60-80 °C with suitable pressure when successful self-humidification is achieved. Below the current density of the point, the stack's performance is inferior at lower RH due to membrane unsaturation, and conversely, the performance is inferior at higher RH due to flooding; this current density decreases with higher pressure and lower temperature.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.