ArticleEuropean radiology2024
Three-dimensional heavily T2-weighted FLAIR in the detection of blood-labyrinthine barrier leakage in patients with sudden sensorineural hearing loss: comparison with T1 sequences and application of deep learning-based reconstruction.
Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Beyond FLAIR: PRISM (polarity-preserving real inversion solute mapping)-a new Frontier in real inversion recovery MRI for intracranial and sensory organ fluid assessment.Japanese journal of radiology · 2026Review
- Optimal MRI protocol for acute unilateral vestibulopathy: 3D-fsFLAIR vs 3D-fsT1WI at multiple post-contrast time points.European radiology · 2026Article
- Combining optimized three-dimensional ZOOMit real inversion recovery with T2-preparation to shorten the delay interval and scan time for endolymphatic hydrops evaluation in patients with Ménière's disease.Quantitative imaging in medicine and surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveBlood-labyrinthine barrier leakage has been reported in sudden sensorineural hearing loss (SSNHL). We compared immediate post-contrast 3D heavily T2-weighted fluid-attenuated inversion recovery (FLAIR), T1 spin echo (SE), and 3D T1 gradient echo (GRE) sequences, and heavily T2-weighted FLAIR (hvT2F) with and without deep learning-based reconstruction (DLR) in detecting perilymphatic enhancement.
methodsFifty-four patients with unilateral SSNHL who underwent ear MRI with three sequences were included. We compared asymmetry scores, confidence scores, and detection rates of perilymphatic enhancement among the three sequences and obtained 3D hvT2F with DLR from 35 patients. The above parameters and subjective image quality between 3D hvT2F with and without DLR were compared.
resultsAsymmetry scores and detection rate of 3D hvT2F were significantly higher than 3D GRE T1 and SE T1 (respectively, 1.37, 0.11, 0.19; p < 0.001). Asymmetry scores significantly increased with DLR compared to 3D hvT2F for experienced and inexperienced readers (respectively, 1.77 vs. 1.40, p = 0.036; 1.49 vs. 1.03, p = 0.012). The detection rate significantly increased only for the latter (57.1% vs. 31.4%, p = 0.022). Patients with perilymphatic enhancement had significantly higher air conduction thresholds on initial (77.96 vs. 57.79, p = 0.002) and 5 days after presentation (63.38 vs. 41.85, p = 0.019).
conclusion3D hvT2F significantly increased the detectability of perilymphatic enhancement compared to 3D GRE T1 and SE T1. DLR further improved the conspicuity of perilymphatic enhancement in 3D hvT2F. 3D hvT2F and DLR are useful for evaluating blood-labyrinthine barrier leakage; furthermore, they might provide prognostic value in the early post-treatment period. CLINICAL RELEVANCE STATEMENT: Ten-minute post-contrast 3D heavily T2-weighed FLAIR imaging is a potentially efficacious sequence in demonstrating perilymphatic enhancement in patients with sudden sensorineural hearing loss and may be further improved by deep learning-based reconstruction. KEY POINTS: • 3D heavily T2-weighted FLAIR (3D hvT2F) is a sequence sensitive in detecting low concentrations of contrast in the perilymphatic space. • 3D hvT2F sequences properly demonstrated perilymphatic enhancement in sudden sensorineural hearing loss compared to T1 sequences and were further improved by deep learning-based reconstruction (DLR). • 3D hvT2F and DLR are efficacious sequences in detecting blood-labyrinthine barrier leakage and with potential prognostic information.
Indexed as
Identifiers
38231393What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.