ArticleCardiovascular ultrasound2024
Cardiac dimensions and hemodynamics in healthy juvenile Landrace swine.
Article in Cardiovascular ultrasound, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 11 citations in OpenAlex.
- Electrocardiographic and echocardiographic profiles of white-lipped peccaries (Frontiers in veterinary science · 2026Article
- Ea/Ees and oscillatory power fraction capture complementary but distinct components of ventriculoarterial coupling: a porcine study.Frontiers in physiology · 2026Article
- Transthoracic echocardiography in healthy Diannan small-ear pigs.BMC cardiovascular disorders · 2025Article
- Echocardiographic assessment of a novel blood-guiding accessory for left ventricular assist devices in swine.Interdisciplinary cardiovascular and thoracic surgery · 2025Article
- Coronary Perfusion Following a Transcatheter Aortic Valve Replacement in Either Reanimated Swine or Preserved Human Hearts.Reviews in cardiovascular medicine · 2025Article
- Standardized subxiphoid echocardiography in swine: procedural guide and reference values.Frontiers in cardiovascular medicine · 2025Article
- Establishing standardized transthoracic echocardiography reference ranges for mouse models: insights into the impact of anesthesia, sex, and age.Frontiers in cardiovascular medicine · 2025Article
- In Vivo Testing of a Second-Generation Prototype Accessory for Single Transapical Left Ventricular Assist Device Implantation.Bioengineering (Basel, Switzerland) · 2024Article
- An early HMGB1 rise 12 hours before creatinine predicts acute kidney injury and multiple organ failure in a smoke inhalation and burn swine model.Frontiers in immunology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundSwine are frequently used as animal model for cardiovascular research, especially in terms of representativity of human anatomy and physiology. Reference values for the most common species used in research are important for planning and execution of animal testing. Transesophageal echocardiography is the gold standard for intraoperative imaging, but can be technically challenging in swine. Its predecessor, epicardial echocardiography (EE), is a simple and fast intraoperative imaging technique, which allows comprehensive and goal-directed assessment. However, there are few echocardiographic studies describing echocardiographic parameters in juvenile swine, none of them using EE. Therefore, in this study, we provide a comprehensive dataset on multiple geometric and functional echocardiographic parameters, as well as basic hemodynamic parameters in swine using EE.
methodsThe data collection was performed during animal testing in ten female swine (German Landrace, 104.4 ± 13.0 kg) before left ventricular assist device implantation. Hemodynamic data was recorded continuously, before and during EE. The herein described echocardiographic measurements were acquired according to a standardized protocol, encompassing apical, left ventricular short axis and long axis as well as epiaortic windows. In total, 50 echocardiographic parameters and 10 hemodynamic parameters were assessed.
resultsEpicardial echocardiography was successfully performed in all animals, with a median screening time of 14 min (interquartile range 11-18 min). Referring to left ventricular function, ejection fraction was 51.6 ± 5.9% and 51.2 ± 6.2% using the Teichholz and Simpson methods, respectively. Calculated ventricular mass was 301.1 ± 64.0 g, as the left ventricular end-systolic and end-diastolic diameters were 35.3 ± 2.5 mm and 48.2 ± 3.5 mm, respectively. The mean heart rate was 103 ± 28 bpm, mean arterial pressure was 101 ± 20 mmHg and mean flow at the common carotid artery was 627 ± 203 mL/min.
conclusionEpicardial echocardiography allows comprehensive assessment of most common echocardiographic parameters. Compared to humans, there are important differences in swine with respect to ventricular mass, size and wall thickness, especially in the right heart. Most hemodynamic parameters were comparable between swine and humans. This data supports study planning, animal and device selection, reinforcing the three R principles in animal research.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials