Effects of non-stationary blur on texture biomarkers of bone using Ultra-High Resolution CT.

G Shi, F J Quevedo Gonzalez, R E Breighner, J A Carrino, J H Siewerdsen, W Zbijewski

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

G ShiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205.
F J Quevedo GonzalezDepartment of Biomechanics, Hospital for Special Surgery, New York, NY USA 10021.
R E BreighnerDepartment of Biomechanics, Hospital for Special Surgery, New York, NY USA 10021.
J A CarrinoHospital for Special Surgery, Radiology & Imaging, New York, NY USA 10021.
J H SiewerdsenMD Anderson Cancer Center, Houston, TX USA 77030.
W ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205.

Funding

Quantitative bone radiomics using Ultra-High Resolution CTR01EB029446 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI ZBIJEWSKI, WOJCIECH BARTOSZ · 2021 to 2024
$1.7M
NIBIB NIH HHS R01 EB029446
6 · The paper itself

Abstract

Purpose: To advance the development of radiomic models of bone quality using the recently introduced Ultra-High Resolution CT (UHR CT), we investigate inter-scan reproducibility of trabecular bone texture features to spatially-variant azimuthal and radial blurs associated with focal spot elongation and gantry rotation. Methods: The UHR CT system features 250×250 μm detector pixels and an x-ray source with a 0.4×0.5 mm focal spot. Visualization of details down to ~150 μm has been reported for this device. A cadaveric femur was imaged on UHR CT at three radial locations within the field-of-view: 0 cm (isocenter), 9 cm from the isocenter, and 18 cm from the isocenter; we expect the non-stationary blurs to worsen with increasing radial displacement. Gray level cooccurrence (GLCM) and gray level run length (GLRLM) texture features were extracted from 237 trabecular regions of interest (ROIs, 5 cm diameter) placed at corresponding locations in the femoral head in scans obtained at the different shifts. We evaluated concordance correlation coefficient (CCC) between texture features at 0 cm (reference) and at 9 cm and 18 cm. We also investigated whether the spatially-variant blurs affect K-means clustering of trabecular bone ROIs based on their texture features. Results: The average CCCs (against the 0 cm reference) for GLCM and GLRM features were ~0.7 at 9 cm. At 18 cm, the average CCCs were reduced to ~0.17 for GLCM and ~0.26 for GLRM. The non-stationary blurs are incorporated in radiomic features of cancellous bone, leading to inconsistencies in clustering of trabecular ROIs between different radial locations: an intersection-over-union overlap of corresponding (most similar) clusters between 0 cm and 9 cm shift was >70%, but dropped to <60% for the majority of corresponding clusters between 0 cm and 18 cm shift. Conclusion: Non-stationary CT system blurs reduce inter-scan reproducibility of texture features of trabecular bone in UHR CT, especially for locations >15 cm from the isocenter. Radiomic models of bone quality derived from UHR CT measurements at isocenter might need to be revised before application in peripheral body sites such as the hips.

Indexed as

bone imagingbone microstructurehigh resolution CTquantitative CTradiomicstexture analysis