Evidence map›Paper›PMID 38225785›Full record

ArticleJournal of Korean medical science2024

First-in-Human Study for Evaluating the Accuracy of Smart Ring Based Cuffless Blood Pressure Measurement.

Jihoon Kim, Sung-A Chang, Seung Woo Park

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Journal of Korean medical science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
2.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07753876 enrolling by invitationnot on this mapstarted 2025, after this paper: background citation

Evaluation of Cuffless Blood Pressure Monitoring in Hemodialysis (CURE-HD) Study

TypeobservationalSponsorGangnam Severance HospitalRan2025 to 2026Enrolled240ConditionsEnd-Stage Renal DiseaseArmsCART BP Pro
NCT07762859 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Wearable Ambulatory Versus Office Blood Pressure-Guided Hypertension Management in Hemodialysis Patients: A Multicenter, Single-Blind, Randomized Controlled Trial

TypeinterventionalSponsorGangnam Severance HospitalRan2026 to 2027Enrolled280ConditionsESRD on HDArmsCART BP Pro-guided blood pressure management, Conventional office blood pressure-guided management
3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Smart Ring in Clinical Medicine: A Systematic Review.Biomimetics (Basel, Switzerland) · 2025
    Review
  11. Digital hypertension - what we need for the high-quality management of hypertension in the new era.Hypertension research : official journal of the Japanese Society of Hypertension · 2025
    Review
  12. Observational
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Jihoon KimDivision of Cardiology, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-6919-446X
Sung-A ChangDivision of Cardiology, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-5124-605X
Seung Woo ParkDivision of Cardiology, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. s.woo.park@samsung.com.ORCID https://orcid.org/0000-0002-2941-515X
Samsung Medical Center · KR

Funding

Samsung Medical Center PHO0223201
6 · The paper itself

Abstract

backgroundRecently, a ring-type cuffless blood pressure (BP) measuring device has been developed. This study was a prospective, single arm, first-in-human pivotal trial to evaluate accuracy of BP measurement by the new device.

methodsThe ring-type smart wearable monitoring device measures photoplethysmography signals from the proximal phalanx and transmits the data wirelessly to a connected smartphone. For the BP comparison, a cuff was worn on the arm to check the reference BP by auscultatory method, while the test device was worn on the finger of the opposite arm to measure BP simultaneously. Measurements were repeated for up to three sets each on the left and right arms. The primary outcome measure was mean difference and standard deviation of BP differences between the test device and the reference readings.

resultsWe obtained 526 sets of systolic BP (SBP) and 513 sets of diastolic BP (DBP) from 89 subjects, with ranges of 80 to 175 mmHg and 43 to 122 mmHg for SBP and DBP, respectively. In sample-wise comparison, the mean difference between the test device and the reference was 0.16 ± 5.90 mmHg (95% limits of agreement [LOA], -11.41, 11.72) in SBP and -0.07 ± 4.68 (95% LOA, -9.26, 9.10) in DBP. The test device showed a strong correlation with the reference for SBP (

conclusionThe new ring-type BP measuring device showed a good correlation for SBP and DBP with minimal bias compared with an auscultatory method.

Indexed as

HypertensionWearable Electronic DevicesBlood PressureBlood Pressure DeterminationHumansProspective StudiesBlood Pressure MonitorsPhotoplethysmographyWearable Electronic Devices

Identifiers

PMID38225785
PMCPMC10789523
OpenAlexW4390221362

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.