Evidence map›Paper›PMID 38225700›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2024

Cleanroom-Free Direct Laser Micropatterning of Polymers for Organic Electrochemical Transistors in Logic Circuits and Glucose Biosensors.

Alessandro Enrico, Sebastian Buchmann, Fabio De Ferrari, Yunfan Lin, Yazhou Wang, Wan Yue, Gustaf Mårtensson, Göran Stemme, Mahiar Max Hamedi, Frank Niklaus and 2 more

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Review
  3. PEDOT:PSS-A Key Material for Bioelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Alessandro EnricoDepartment of Micro and Nanosystems, KTH Royal Institute of Technology, Malvinas väg 10, Stockholm, 100 44, Sweden.ORCID https://orcid.org/0000-0002-8821-6759
Sebastian BuchmannDivision of Nanobiotechnology, SciLifeLab, Department of Protein Science, KTH Royal Institute of Technology, Tomtebodavägen 23a, Solna, 171 65, Sweden.ORCID https://orcid.org/0000-0001-7442-3020
Fabio De FerrariDepartment of Micro and Nanosystems, KTH Royal Institute of Technology, Malvinas väg 10, Stockholm, 100 44, Sweden.ORCID https://orcid.org/0000-0003-0960-9931
Yunfan LinDivision of Nanobiotechnology, SciLifeLab, Department of Protein Science, KTH Royal Institute of Technology, Tomtebodavägen 23a, Solna, 171 65, Sweden.ORCID https://orcid.org/0000-0002-6560-5209
Yazhou WangGuangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, School of Materials Science and Engineering, Sun Yat-sen University, Guangzhou, 510275, P. R. China.
Wan YueKey Laboratory for Polymeric Composite and Functional Materials of Ministry of Education, School of Materials Science and Engineering, Sun Yat-sen University, Guangzhou, 510275, P. R. China.
Gustaf MårtenssonDivision of Nanobiotechnology, SciLifeLab, Department of Protein Science, KTH Royal Institute of Technology, Tomtebodavägen 23a, Solna, 171 65, Sweden.ORCID https://orcid.org/0000-0002-6041-4980
Göran StemmeDepartment of Micro and Nanosystems, KTH Royal Institute of Technology, Malvinas väg 10, Stockholm, 100 44, Sweden.ORCID https://orcid.org/0000-0001-9552-4234
Mahiar Max HamediDepartment of Fibre and Polymer Technology, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden.ORCID https://orcid.org/0000-0001-9088-1064
Frank NiklausDepartment of Micro and Nanosystems, KTH Royal Institute of Technology, Malvinas väg 10, Stockholm, 100 44, Sweden.ORCID https://orcid.org/0000-0002-0525-8647
Anna HerlandDivision of Nanobiotechnology, SciLifeLab, Department of Protein Science, KTH Royal Institute of Technology, Tomtebodavägen 23a, Solna, 171 65, Sweden.ORCID https://orcid.org/0000-0002-5002-2537
Erica ZeglioDivision of Nanobiotechnology, SciLifeLab, Department of Protein Science, KTH Royal Institute of Technology, Tomtebodavägen 23a, Solna, 171 65, Sweden.ORCID https://orcid.org/0000-0002-6428-0633

Funding

Formas - a Swedish Research Council for Sustainable Development 2022-00374Fundamental Research Funds for the Central UniversitiesGetinge AB 4.1599/2018H2020 Marie Skłodowska-Curie Actions 101025599Karolinska Institutet 1-249/2019Knut and Alice Wallenberg Foundation 2015.0178Knut and Alice Wallenberg Foundation 2020.0206Knut and Alice Wallenberg Foundation 2021.0312KTH Royal Institute of Technology VF-2019-0110Sun Yat-sen University 23yxqntd002Vetenskapsrådet 2018-03483Vetenskapsrådet 2022-02855Vetenskapsrådet 2022-04060Wallenberg Initiative Materials Science for Sustainability
6 · The paper itself

Abstract

Organic electrochemical transistors (OECTs) are promising devices for bioelectronics, such as biosensors. However, current cleanroom-based microfabrication of OECTs hinders fast prototyping and widespread adoption of this technology for low-volume, low-cost applications. To address this limitation, a versatile and scalable approach for ultrafast laser microfabrication of OECTs is herein reported, where a femtosecond laser to pattern insulating polymers (such as parylene C or polyimide) is first used, exposing the underlying metal electrodes serving as transistor terminals (source, drain, or gate). After the first patterning step, conducting polymers, such as poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS), or semiconducting polymers, are spin-coated on the device surface. Another femtosecond laser patterning step subsequently defines the active polymer area contributing to the OECT performance by disconnecting the channel and gate from the surrounding spin-coated film. The effective OECT width can be defined with high resolution (down to 2 µm) in less than a second of exposure. Micropatterning the OECT channel area significantly improved the transistor switching performance in the case of PEDOT:PSS-based transistors, speeding up the devices by two orders of magnitude. The utility of this OECT manufacturing approach is demonstrated by fabricating complementary logic (inverters) and glucose biosensors, thereby showing its potential to accelerate OECT research.

Indexed as

conjugated polymerdirect writingorganic electrochemical transistorpoly(3,4‐ethylenedioxythiophene) polystyrene sulfonateultrashort pulsed lasers

Identifiers

PMID38225700
PMCPMC11251563

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390