Evidence map›Paper›PMID 38224383›Full record

ArticlePhysical and engineering sciences in medicine2024

Comparison of skin dose in IMRT and VMAT with TrueBeam and Halcyon linear accelerator for whole breast irradiation.

Jae Hyun Seok, So Hyun Ahn, Woo Sang Ahn, Dong Hyeok Choi, Seong Soo Shin, Wonsik Choi, In-Hye Jung, Rena Lee, Jin Sung Kim

Erratum issuedOpen access · hybridAbstract readComparative Study
In one paragraph

Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Jae Hyun SeokDepartment of Integrative Medicine, Yonsei University College of Medicine, Seoul, Korea.
So Hyun Ahn *Ewha Medical Research Institute, Ewha Womans University College of Medicine, Seoul, Korea. mpsohyun@gmail.com.ORCID http://orcid.org/0000-0002-0116-3325
Woo Sang Ahn *Department of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea. anidol@ulsan.ac.kr.
Dong Hyeok ChoiMedical Physics and Biomedical Engineering Lab (MPBEL), Yonsei University College of Medicine, Seoul, Korea.
Seong Soo ShinDepartment of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea.
Wonsik ChoiDepartment of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea.
In-Hye JungDepartment of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea.
Rena LeeDepartment of Biomedical Engineering, Ewha Womans University, Seoul, Korea.
Jin Sung KimMedical Physics and Biomedical Engineering Lab (MPBEL), Yonsei University College of Medicine, Seoul, Korea.
Ulsan College · KRYonsei University · KREwha Womans University · KREwha Womans University Medical Center · KR

Funding

Gangneung Asan Hospital 2021IC003Korea Institute of Energy Technology Evaluation and Planning 20227410100050Ministry of Education NRF-2022R1H1A2092091
6 · The paper itself

Abstract

With the increasing use of flattening filter free (FFF) beams, it is important to evaluate the impact on the skin dose and target coverage of breast cancer treatments. This study aimed to compare skin doses of treatments using FFF and flattening filter (FF) beams for breast cancer. The study established treatment plans for left breast of an anthropomorphic phantom using Halcyon's 6-MV FFF beam and TrueBeam's 6-MV FF beam. Volumetric modulated arc therapy (VMAT) with varying numbers of arcs and intensity modulated radiation therapy (IMRT) were employed, and skin doses were measured at five points using Gafchromic EBT3 film. Each measurement was repeated three times, and averaged to reduce uncertainty. All plans were compared in terms of plan quality to ensure homogeneous target coverage. The study found that when using VMAT with two, four, and six arcs, in-field doses were 19%, 15%, and 6% higher, respectively, when using Halcyon compared to TrueBeam. Additionally, when using two arcs for VMAT, in-field doses were 10% and 15% higher compared to four and six arcs when using Halcyon. Finally, in-field dose from Halcyon using IMRT was about 1% higher than when using TrueBeam. Our research confirmed that when treating breast cancer with FFF beams, skin dose is higher than with traditional FF beams. Moreover, number of arcs used in VMAT treatment with FFF beams affects skin dose to the patient. To maintain a skin dose similar to that of FF beams when using Halcyon, it may be worth considering increasing the number of arcs.

Indexed as

Breast NeoplasmsParticle AcceleratorsPhantoms, ImagingRadiotherapy DosageRadiotherapy, Intensity-ModulatedSkinBreastDose-Response Relationship, RadiationFemaleHumansRadiation DosageRadiotherapy Planning, Computer-AssistedBreast cancerFFF beamHalcyonO-ring-type linacSkin dose

Identifiers

PMID38224383
PMCPMC11166860
OpenAlexW4390885863

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.