ArticleProceedings of SPIE--the International Society for Optical Engineering

Feasibility of Dual-Energy Cone-Beam CT of Bone Marrow Edema Using Dual-Layer Flat Panel Detectors.

Stephen Z Liu, Chumin Zhao, Magdalena Herbst, Thomas Weber, Sebastian Vogt, Ludwig Ritschl, Steffen Kappler, Jeffrey H Siewerdsen, Wojciech Zbijewski

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.9field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Quantitative Dual-Energy Imaging of Bone Marrow Edema Using Multisource Cone-Beam CT with Model-Based Decomposition.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  5. Article
  6. Dual-Energy Cone-Beam CT with Three-Material Decomposition for Bone Marrow Edema Imaging.Proceedings of SPIE--the International Society for Optical Engineering · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Stephen Z LiuDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205.
Chumin ZhaoDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205.
Magdalena HerbstSiemens Healthineers, Forchhelm 91301, Germany.
Thomas WeberSiemens Healthineers, Forchhelm 91301, Germany.
Sebastian VogtSiemens Healthineers, Forchhelm 91301, Germany.
Ludwig RitschlSiemens Healthineers, Forchhelm 91301, Germany.
Steffen KapplerSiemens Healthineers, Forchhelm 91301, Germany.
Jeffrey H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205.
Wojciech ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205.
Johns Hopkins University · USSiemens Healthcare (Germany) · DESiemens Healthcare (United States) · US

Funding

Monitoring of fractures with internal fixators using weight-bearing quantitative cone beam CTR01EB025470 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER, ZBIJEWSKI, WOJCIECH BARTOSZ · 2018 to 2021
$1.5M
NIBIB NIH HHS R01 EB025470
6 · The paper itself

Abstract

Purpose: We investigated the feasibility of detection and quantification of bone marrow edema (BME) using dual-energy (DE) Cone-Beam CT (CBCT) with a dual-layer flat panel detector (FPD) and three-material decomposition. Methods: A realistic CBCT system simulator was applied to study the impact of detector quantization, scatter, and spectral calibration errors on the accuracy of fat-water-bone decompositions of dual-layer projections. The CBCT system featured 975 mm source-axis distance, 1,362 mm source-detector distance and a 430 × 430 mm Results: The decomposition is sensitive to scatter: approx. <20 mm collimation width or <10% error of scatter correction in a full field-of-view setting is needed to resolve BME. A mismatch in PDD decomposition calibration of ± 1 keV results in ~25% error in fat fraction estimates. In the wrist phantom study with MC scatter corrections, we were able to achieve ~0.79 mL true positive and ~0.06 mL false positive BME detection (compared to 0.85 mL true BME volume). Conclusions: Detection of BME using DE CBCT with dual-layer FPD is feasible, but requires scatter mitigation, accurate scatter estimation, and robust spectral calibration.

Indexed as

bone marrow lesionscone-beam CTdual-energy CTmulti-layer detectormulti-material decompositionx-ray scatter correction

Identifiers

PMID38223908
PMCPMC10788135
OpenAlexW4220981122

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.