Evidence map›Paper›PMID 38223382›Full record

ArticleJDS communications2024

Association between a pyroelectric infrared sensor monitoring system and a 3-dimensional accelerometer to assess movement in preweaning dairy calves.

N Sonntag, S Borchardt, W Heuwieser, F Sutter

Abstract read
In one paragraph

Article in JDS communications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

N SonntagClinic for Animal Reproduction, Faculty of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany.
S BorchardtClinic for Animal Reproduction, Faculty of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany.
W HeuwieserClinic for Animal Reproduction, Faculty of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany.
F SutterClinic for Animal Reproduction, Faculty of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of this study was to correlate movement assessed by a pyroelectric infrared sensor system in preweaning dairy calves with lying and standing time assessed by a 3D accelerometer considering the temperature-humidity index (THI). A total of 35 dairy calves (1-7 d of age) were enrolled in the study and 20 calves were included in the final analyses. The lying and standing time of the calves was monitored with a 3D accelerometer (Hobo Pendant G Data Logger, Onset Computer Corporation, USA), which was used as the gold standard reference. The infrared sensor monitoring system (IMS; Calf Monitoring System, Futuro Farming GmbH, Germany) was fixed to the fence of the calf hutch within the calf's reach. Temperature-humidity was monitored with 2 validated THI sensors inside and on outside of each calf hutch. Additionally, one THI sensor was located near the calf hutches. The observation period lasted 14 consecutive days. The average standing time assessed by the 3D accelerometer was 13.4 ± 12.7 (mean ± standard deviation) min/h and the average lying time was 46.6 (±12.7) min/h. The median (25th percentile; 75th percentile) number of movements measured by the IMS was 360 (60; 919) movements per hour. Number of movements per hour measured by the IMS was compared with data obtained with a validated 3D accelerometer. The Pearson correlation coefficient between both standing and lying time and the number of movements was r = 0.85 and r = -0.85, respectively. The Pearson correlation coefficients were only slightly influenced by THI (low THI [<68]: r = 0.86; medium THI [68-72]: r = 0.85; high THI [>72]: r = 0.81). Our data show that the number of movements of dairy calves measured by IMS were highly correlated with the chosen gold standard reference method. High THI slightly affects the measurement accuracy of IMS.

Identifiers

PMID38223382
PMCPMC10785259

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.