ArticleQuantitative imaging in medicine and surgery2024
Development and validation of a deep-learning model for the detection of non-displaced femoral neck fractures with anteroposterior and lateral hip radiographs.
Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 5 citations in OpenAlex.
- Between Accessibility and Reliability: High Confidence, Low Control in General-Purpose Multimodal Models for Hip Fracture Radiograph Interpretation.Journal of clinical medicine · 2026Article
- Optimizing treatment strategies for femoral neck fractures using a machine learning model.Journal of orthopaedic surgery and research · 2026Article
- Who Is the Surgeon Now: Human Hands or Machine Minds? Artificial Intelligence in Orthopedics from Diagnosis to Follow-Up-A Structured Narrative Review.Journal of clinical medicine · 2026Review
- Article
- Development and validation of a deep learning-based automatic detection and classification model for femoral neck fractures using hip imaging: a retrospective multicenter diagnostic study.Frontiers in medicine · 2026Article
- A deep learning framework for automated fracture detection and localization in radiographic images using convolutional neural networks.Frontiers in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Hip fractures, including femoral neck fractures, are a significant cause of morbidity and mortality in the elderly population and are typically diagnosed using plain radiography. However, diagnosing non-displaced femoral neck fractures can be challenging due to their subtle appearance on hip radiographs. Previous deep-learning models have shown low accuracy in identifying these fractures on anteroposterior (AP) radiographs; however, no studies have used lateral radiographs. This study aimed to evaluate the potential of using deep-learning with both AP and lateral hip radiographs to automatically identify non-displaced femoral neck fractures. Methods: We conducted a retrospective analysis of patients with femoral neck fractures at The First Affiliated Hospital of Xiamen University. All the hip radiographs were reviewed, and cases of non-displaced femoral neck fractures were included in the study. Additionally, 439 participants with normal hip radiographs were also included in the study. A vision transformer (Vit) model was developed using 1,536 AP and lateral hip radiograph. The model's performance was compared to the performance of two groups of human observers: an expert group comprising orthopedic surgeons and radiologists, and a non-expert group, including emergency physicians and general practice doctors. We also carried out the external validation using two additional data sets to assess the generalizability of the model. Results: The Vit model showed exceptional performance in detecting non-displaced femoral neck fractures on paired AP and lateral hip radiographs, achieving a binary accuracy of 95.8% [95% confidence interval (CI): 94.9%, 96.8%] and an area under the curve (AUC) of 0.988. Compared to the human observers, the model had a higher accuracy of 96.7% (95% CI: 93.9%, 99.5%) on the paired AP and lateral hip radiographs, while the accuracy of the expert group was 90.5% (95% CI: 85.7%, 95.2%). Further, the model maintained good performance during the external validation, with an AUC of 0.959 on the paired AP and lateral views. Conclusions: Our Vit model showed expert-level performance in identifying non-displaced femoral neck fractures on paired AP and lateral hip radiographs. This model has the potential to enhance diagnosis accuracy and improve patient outcomes by reducing the need for additional examinations and preoperative time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.