Evidence map›Paper›PMID 38223075›Full record

ArticleQuantitative imaging in medicine and surgery2024

Utility of spectral CT with orthopedic metal artifact reduction algorithms for

Yuhan Zhou, Limin Lei, Zhihao Wang, Weimeng Cao, Minghui Qin, Shushan Dong, Jinjin Dang, Zhigang Zhou

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Yuhan Zhou *Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Limin Lei *Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Zhihao WangDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Weimeng CaoDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Minghui QinDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Shushan DongDepartment of Clinical Science, Philips Healthcare, Beijing, China.
Jinjin DangDepartment of Clinical Science, Philips Healthcare, Beijing, China.
Zhigang ZhouDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
First Affiliated Hospital of Zhengzhou University · CNPhilips (China) · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Virtual monochromatic image (VMI) combined with orthopedic metal artifact reduction algorithms (VMI + O-MAR) can effectively reduce artifacts caused by metal implants of different types. Nevertheless, so far, no study has systematically evaluated the efficacy of VMI + O-MAR in reducing various types of metal artifacts induced by Methods: A total of 45 patients who underwent dual-layer detector spectral CT (DLCT; IQon, Philips Healthcare) scanning of mediastinal and hepatic tumors after Results: In artifact-affected lesion areas, SNR and CNR in the CI/VMI + O-MAR groups were better than those in CI groups (all P values <0.05). The AI showed a downward trend as VMI keV increased (all P values <0.001). The AI values of the CI/VMI (50-150 keV) group were all higher than the groups of CI/VMI + O-MAR (50-150 keV) (P<0.001). Overcorrection artifacts and new artifacts were concentrated in the VMI50/70 keV groups. In the evaluation of artifact morphology, as the VMI keV increased, the number of near-field banding artifacts in hyperdense artifacts gradually decreased, whereas the number of minimal or no artifacts increased, and the total number of hyperdense artifacts were decreased. The diagnostic and image quality scores of hyperdense artifacts were higher than those of hypodense artifacts as VMI keV increased. Conclusions: High VMI level combined with O-MAR substantially improve objective and subjective image quality, lesion display ability, and diagnostic confidence of CT follow-up after

Indexed as

125I radioactive seeds implantation (125I RSI)Dual-layer spectral CTimage quality assessmentorthopedic metal artifact reduction algorithms (O-MAR)virtual monochromatic image (VMI)

Identifiers

PMID38223075
PMCPMC10784080
OpenAlexW4390428867

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.