Evidence map›Paper›PMID 38223037›Full record

ArticleQuantitative imaging in medicine and surgery2024

Impact of deep learning-based reconstruction and anti-peristaltic agent on the image quality and diagnostic performance of magnetic resonance enterography comparing single breath-hold single-shot fast spin echo with and without anti-peristaltic agent.

Eun Joo Park, Yedaun Lee, Ho-Joon Lee, Jung Hee Son, Jisook Yi, Seok Hahn, Joonsung Lee

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Eun Joo ParkDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Yedaun LeeDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Ho-Joon LeeDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Jung Hee SonDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Jisook YiDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Seok HahnDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Joonsung LeeGE HealthCare Korea, Seoul, Republic of Korea.
Inje University Haeundae Paik Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: While anti-peristaltic agents are beneficial for high quality magnetic resonance enterography (MRE), their use is constrained by potential side effects and increased examination complexity. We explored the potential of deep learning-based reconstruction (DLR) to compensate for the absence of anti-peristaltic agent, improve image quality and reduce artifact. This study aimed to evaluate the need for an anti-peristaltic agent in single breath-hold single-shot fast spin-echo (SSFSE) MRE and compare the image quality and artifacts between conventional reconstruction (CR) and DLR. Methods: We included 45 patients who underwent MRE for Crohn's disease between October 2021 and September 2022. Coronal SSFSE images without fat saturation were acquired before and after anti-peristaltic agent administration. Four sets of data were generated: SSFSE CR with and without an anti-peristaltic agent (CR-A and CR-NA, respectively) and SSFSE DLR with and without an anti-peristaltic agent (DLR-A and DLR-NA, respectively). Two radiologists independently reviewed the images for overall quality and artifacts, and compared the three images with DLR-A. The degree of distension and inflammatory parameters were scored on a 5-point scale in the jejunum and ileum, respectively. Signal-to-noise ratio (SNR) levels were calculated in superior mesenteric artery (SMA) and iliac bifurcation level. Results: In terms of overall quality, DLR-NA demonstrated no significant difference compared to DLR-A, whereas CR-NA and CR-A demonstrated significant differences (P<0.05, both readers). Regarding overall artifacts, reader 1 rated DLR-A slightly better than DLR-NA in four cases and rated them as identical in 41 cases (P=0.046), whereas reader 2 demonstrated no difference. Bowel distension was significantly different in the jejunum (Reader 1: P=0.046; Reader 2: P=0.008) but not in the ileum. Agreements between the images (Reader 1: ĸ=0.73-1.00; Reader 2: ĸ=1.00) and readers (ĸ=0.66 for all comparisons) on inflammation were considered good to excellent. The sensitivity, specificity, and accuracy in diagnosing inflammation in the terminal ileum were the same among DLR-NA, DLR-A, CR-NA and CR-A (94.42%, 81.83%, and 89.69 %; and 83.33%, 90.91%, and 86.21% for Readers 1 and 2, respectively). In both SMA and iliac bifurcation levels, SNR of DLR images exhibited no significant differences. CR images showed significantly lower SNR compared with DLR images (P<0.001). Conclusions: SSFSE without anti-peristaltic agents demonstrated nearly equivalent quality to that with anti-peristaltic agents. Omitting anti-peristaltic agents before SSFSE and adding DLR could improve the scanning outcomes and reduce time.

Indexed as

anti-peristaltic agentsdeep learning-based reconstruction (DLR)Magnetic resonance enterography (MRE)

Identifiers

PMID38223037
PMCPMC10784037
OpenAlexW4390428472

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.