Evidence map›Paper›PMID 38219714›Full record

ArticleStereotactic and functional neurosurgery2024

General Algorithm Applicability in Determining DBS Lead Orientation: Adapting 2D and 3D X-Ray Techniques for SenSightTM Leads.

Stefan Hunsche, Dieter Fedders, Alexandra Hellerbach, Markus Eichner, Jochen Wirths, Till A Dembek, Veerle Visser-Vandewalle, Harald Treuer

Abstract read
In one paragraph

Article in Stereotactic and functional neurosurgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Stefan HunscheDepartment of Stereotactic and Functional Neurosurgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Cologne, Germany.
Dieter FeddersInstitute and Policlinic for Diagnostic and Interventional Radiology, Technical University Dresden, Dresden, Germany.
Alexandra HellerbachDepartment of Stereotactic and Functional Neurosurgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Cologne, Germany.
Markus EichnerDepartment of Stereotactic and Functional Neurosurgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Cologne, Germany.
Jochen WirthsDepartment of Stereotactic and Functional Neurosurgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Cologne, Germany.
Till A DembekDepartment of Neurology, University Hospital Cologne and Faculty of Medicine, University of Cologne, Cologne, Germany.
Veerle Visser-VandewalleDepartment of Stereotactic and Functional Neurosurgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Cologne, Germany.
Harald TreuerDepartment of Stereotactic and Functional Neurosurgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Cologne, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionWith recent advancements in deep brain stimulation (DBS), directional leads featuring segmented contacts have been introduced, allowing for targeted stimulation of specific brain regions. Given that manufacturers employ diverse markers for lead orientation, our investigation focuses on the adaptability of the 2017 techniques proposed by the Cologne research group for lead orientation determination.

methodsWe tailored the two separate 2D and 3D X-ray-based techniques published in 2017 and originally developed for C-shaped markers, to the dual-marker of the Medtronic SenSight™ lead. In a retrospective patient study, we evaluated their feasibility and consistency by comparing the degree of agreement between the two methods.

resultsThe Bland-Altman plot showed favorable concordance without any noticeable systematic errors. The mean difference was 0.79°, with limits of agreement spanning from 21.4° to -19.8°. The algorithms demonstrated high reliability, evidenced by an intraclass correlation coefficient of 0.99 (p < 0.001).

conclusionThe 2D and 3D algorithms, initially formulated for discerning the circular orientation of a C-shaped marker, were adapted to the marker of the Medtronic SenSight™ lead. Statistical analyses revealed a significant level of agreement between the two methods. Our findings highlight the adaptability of these algorithms to different markers, achievable through both low-dose intraoperative 2D X-ray imaging and standard CT imaging.

Indexed as

Deep Brain StimulationAlgorithmsElectrodes, ImplantedHumansReproducibility of ResultsRetrospective StudiesX-RaysAxial steeringDeep brain stimulationDirectional deep brain stimulationDirectional leadsOrientation angleSegmented electrodes

Identifiers

PMID38219714
PMCPMC10997254

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.