ArticleUltrasonics sonochemistry2024
Efficient and eco-friendly cadmium ion recycling: Ultrasonic enhancement of aluminum powder replacement for low-temperature industrial applications.
Article in Ultrasonics sonochemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Ultrasonic pre-treatment on the replacement of high concentration of cadmium(Ⅱ) by aluminum powder: Effect and mechanism.Ultrasonics sonochemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Replacing cadmium ions in cadmium-containing solutions with aluminum powder is beneficial for cadmium resource recycling and environmental protection. However, the conventional aluminum powder replacement method requires harsh temperatures and prolonged conditions. In this study, the effect and mechanism of ultrasound on the replacement of cadmium with aluminum powder were investigated at low temperatures. Ultrasound has been proven to promote the etching of alumina films through the use of TEM and XPS, providing mechanistic support for the superiority of the new process. A degree of Cd replacement as high as 95.08 % is achieved at a low temperature (60 ℃) and in a short time (20 min) when using ultrasonicated aluminum powder replacement, which is 42.17 % higher than that of conventional aluminum powder. Compared with conventional aluminum powder replacement conditions with the same effect, the introduction of ultrasound can reduce the temperature by 30℃ and shorten the replacement time by 2/3, which has significant advantages in reaction efficiency and safety. The strengthening mechanism of ultrasound on the replacement effect of aluminum powder at low temperatures is revealed through detailed discussions on the corrosion of alumina films, agglomeration of aluminum powder, and adhesion of replacement products to the surface of aluminum powder, dissolved oxygen in the solution, and redissolution of cadmium. Therefore, a new approach for replacing aluminum powder in solutions with high Cd
Indexed as
Identifiers
What OpenQuestion holds
Registered trials