ArticlePediatric research2024
Comparison of positive pressure ventilation devices during compliance changes in a neonatal ovine model.
Article in Pediatric research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
- Volume targeted mask ventilation during simulated neonatal resuscitation - A randomized crossover manikin study.Resuscitation plus · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundTo compare tidal volume (V DESIGN/
methodsRandomized experimental animal study using 10 mixed-breed neonatal piglets (1-3 days; 1.8-2.4 kg). Piglets were anesthetized, intubated, instrumented, and randomized to receive positive pressure ventilation (PPV) for one minute with a SIB with or without a respiratory function monitor (RFM), T-Piece resuscitator with or without an RFM, Next Step, and Fabian Ventilator with both compliance levels. Compliance changes were achieved by placing a wrap around the piglets' chest and tightened it. Our primary outcome was targeted V
resultsAt 0.5 mL/cmH
conclusionThe Next Step provides consistent V IMPACT: Current guidelines recommend fixed peak inflation pressure in resuscitation, linked to lung and brain injury. The Next Step Neonatal Resuscitator, a cost-effective device, offers volume-targeted positive pressure ventilation with consistent tidal volumes. With two different compliances, the Next Step Neonatal Resuscitator delivered a consistent tidal volume which was similar to a mechanical ventilator. The Next Step Neonatal Resuscitator outperformed self-inflating bags and T-Pieces in delivering targeted tidal volumes. The Next Step Neonatal Resuscitator could be an alternative ventilation device for neonatal resuscitation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials