ArticleScientific reports2024
Varus placement of the tibial component reduces the potential risk of fracture with adequate bony coverage in the Oxford unicompartmental knee arthroplasty.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 9 citations in OpenAlex.
- Article
- Radiolucent lines after robotic-assisted surface-matching kinematically aligned UKA: short-term incidence and lack of association with tibial alignment.Archives of orthopaedic and trauma surgery · 2026Article
- Favorable midterm clinical results of medial unicompartmental knee arthroplasty guided by coronal limb alignment using an image-free navigation system.Archives of orthopaedic and trauma surgery · 2026Article
- Investigation of component alignment and patient factors for the risk of subsidence in cementless unicompartmental knee arthroplasty.Archives of orthopaedic and trauma surgery · 2026Article
- Valgus positioning of the femoral component does not compromise short-term clinical outcomes in fixed-bearing unicompartmental knee arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Article
- Surgical factors that contribute to tibial periprosthetic fracture after cementless Oxford Unicompartmental Knee Replacement: a finite element analysis.Frontiers in bioengineering and biotechnology · 2025Article
- [Successful medial unicompartmental knee arthroplasty-What are the most important surgical tricks?]Orthopadie (Heidelberg, Germany) · 2024Review
- Factors predicting lower limb alignment after Oxford medial unicompartmental knee arthroplasty.Scientific reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A short keel-cortex distance (KCD), especially to the posterior cortex, is a potential risk factor for tibial plateau fracture after Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). This study aimed to evaluate the effect of tibial component alignment in the coronal plane and tibial proximal morphology on the KCD. Included in this study were 51 patients scheduled for primary Oxford medial unicompartmental knee arthroplasty (UKA). The anterior and posterior KCD were preoperatively assessed using 3D simulation software with the component set perpendicular to the tibial mechanical axis (neutral), 3° valgus, 3° varus, and 6° varus, relative to neutral alignment. We evaluated the existence of overhanging medial tibial condyle where the medial eminence line, the line including the medial tibial eminence parallel to the tibial axis, passes outside of the tibial shaft. In all component alignments, patients with a medial overhanging condyle had significantly shorter posterior KCD than those without. In patients with a medial overhanging condyle, the posterior KCD significantly increased when the tibial component was placed in 3° varus (4.6 ± 1.5 mm, P = 0.003 vs neutral, P < 0.001 vs 3° valgus) and 6° varus (5.0 ± 1.4 mm, P < 0.001 vs neutral, P < 0.001 vs 3° valgus) compared with in neutral (3.5 ± 1.9 mm) or 3° valgus (2.8 ± 1.8 mm). In OUKA, varus implantation increased the KCD. This could potentially decrease the risk of fracture, even in knees with the overhanging medial condyle. Conversely, valgus implantation of the tibial component shortened the KCD, and should therefore be avoided.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.