Evidence map›Paper›PMID 38218314›Full record

ArticleIndian heart journal

Transcatheter aortic valve implantation using coplanar and cuspal overlap techniques in Indian patients.

Rajat Datta, Prashant Bharadwaj, G Keshavamurthy, Vivek Singh Guleria, Ratheesh Kj, Anil Kumar Abbot

Abstract read
In one paragraph

Article in Indian heart journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Rajat DattaDepartment of Cardiology, AHRR, Delhi, India. Electronic address: drrajatdatta@gmail.com.
Prashant BharadwajDepartment of Cardiology, AHRR, Delhi, India. Electronic address: prashantbharadwaj@gmail.com.
G KeshavamurthyDepartment of Cardiology, AHRR, Delhi, India. Electronic address: keshavamurthyg@gmail.com.
Vivek Singh GuleriaDepartment of Cardiology, AHRR, Delhi, India. Electronic address: viveksguleria@gmail.com.
Ratheesh KjDepartment of Cardiology, AHRR, Delhi, India. Electronic address: ratheeshkj@yahoo.co.in.
Anil Kumar AbbotDepartment of Cardiology, AHRR, Delhi, India. Electronic address: dr_akabbot@yahoo.co.in.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionTranscatheter Aortic Valve Implantation (TAVI) techniques gradually evolved since 2002 and have undergone various refinements. Achieving optimal implantation depth has become crucial for good long term outcome. High implantation decreases the likelihood of conduction disturbances. Conventionally TAVI valve is positioned in a tricusp coplanar (CON) fluoroscopic projection however it does not ensure a optimal implantation. In an attempt to attain higher implantation(3 mm) and decrease rate of permanent pacemaker, cuspal overlap technique (COT) view has been developed. There is scarcity of Indian literature comparing TAVI deployment using coplanar and cuspal overlap techniques.

methodsWe included 111 patients who underwent TAVR with a self-expanding Core Valve Evolut R (Medtronic, Minneapolis, Minnesota), between January 2017 to September 2022 at our centre.Transcatheter Heart Valves (THV) were implanted using the traditional coplanar in 55 patients, while in 56 patients valves were implanted using the COT.

resultsBaseline characteristics including electrocardiographic findings were comparable in both groups. In all patients Evolut R or Evolut PRO valves were used. Procedure was done in conscious sedation in 90.9 % of patients in CON and 96.4 % in COT group. Predilatation and postdilatation was used in 38.8 % vs 33.9 % and 27 % vs 32 % in CON and COT groups respectively. 90 day PPI rate was less in COT group (7.3 % CON vs 3.5 % COP). Majority of patients who received permanent pacemaker implantation (PPI) had baseline ECG abnormality (RBBB in 50 %, LBBB in 16 %, Grade 1 AV block 16 %). Mean time of post procedure PPI was 5.6 days in COT group and 7.3 days in CON group. New onset LBBB was also less in COT group (21 % CON vs 12.5 % COT).There were 3.6 % intraprocedural deaths in CON group and 1.8 % in COT group. Depth of deployed valve was 4.8 ± 2.34 mm in COT and 6.6 ± 2.11 mm in CON group. Valve deployment time was more in COT group(10.40 CON vs 14.34 min COT). Average valve recapture rate was 2.58 in COP and 2.11 in CON. Stroke rate was more in COT group(3.6 % CON vs 7.14 % COT). Pericardial effusions were also more in COT group. All cause mortality at 3 months was 10.9 % in CON group and 5.3 % in COT.

conclusionIn this study we achieved lower rates of PPI and new onset LBBB using COT technique in Indian patients using self-expandable prostheses. However valve deployment time, stroke rate and pericardial effusion were seen more in COT group. All cause mortality was low in cuspal overlap technique.

Indexed as

Heart Valve ProsthesisStrokeTranscatheter Aortic Valve ReplacementElectrocardiographyHumansTreatment OutcomeAortic stenosisCuspal overlap techniquePermanent pacemaker implantationTranscatheter aortic valve replacementTricusp coplanar technique

Identifiers

PMID38218314
PMCPMC10943560

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.