Evidence map›Paper›PMID 38211655›Full record

Observational studyJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2024

Three-dimensional aortic geometry mapping via registration of non-gated contrast-enhanced or gated and respiratory-navigated MR angiographies.

Lydia Dux-Santoy, Jose F Rodríguez-Palomares, Gisela Teixidó-Turà, Juan Garrido-Oliver, Alejandro Carrasco-Poves, Alberto Morales-Galán, Aroa Ruiz-Muñoz, Guillem Casas, Filipa Valente, Laura Galian-Gay and 8 more

Erratum issuedOpen access · goldAbstract readObservational StudyComparative Study
In one paragraph

Observational study in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

18 authors at 4 institutions in 1 country.

Lydia Dux-SantoyVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain. Electronic address: lydia.duxsantoy@vhir.org.
Jose F Rodríguez-PalomaresVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; CIBER de Enfermedades Cardiovasculares, CIBER-CV, Instituto de Salud Carlos III, Madrid, Spain; Department of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Departament of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain. Electronic address: josefernando.rodriguez@vallhebron.cat.
Gisela Teixidó-TuràVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; CIBER de Enfermedades Cardiovasculares, CIBER-CV, Instituto de Salud Carlos III, Madrid, Spain; Department of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Juan Garrido-OliverVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; Departament of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain.
Alejandro Carrasco-PovesVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; Departament of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain.
Alberto Morales-GalánVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain.
Aroa Ruiz-MuñozVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; CIBER de Enfermedades Cardiovasculares, CIBER-CV, Instituto de Salud Carlos III, Madrid, Spain.
Guillem CasasDepartment of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Filipa ValenteDepartment of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Laura Galian-GayCIBER de Enfermedades Cardiovasculares, CIBER-CV, Instituto de Salud Carlos III, Madrid, Spain; Department of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Rubén Fernández-GaleraDepartment of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Ruperto OliveróDepartment of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Hug Cuéllar-CalabriaVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; Departament of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain; Department of Radiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Albert RoqueVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; Departament of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain; Department of Radiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Gemma BurcetVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; Departament of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain; Department of Radiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
José A BarrabésVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; CIBER de Enfermedades Cardiovasculares, CIBER-CV, Instituto de Salud Carlos III, Madrid, Spain; Department of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Departament of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain.
Ignacio Ferreira-GonzálezVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; Department of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Departament of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain; CIBER de Epidemiología y Salud Pública, CIBERESP, Instituto de Salud Carlos III, Madrid, Spain. Electronic address: ignacio.ferreira@vallhebron.cat.
Andrea GualaVall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; CIBER de Enfermedades Cardiovasculares, CIBER-CV, Instituto de Salud Carlos III, Madrid, Spain.
Universitat Autònoma de Barcelona · ESInstituto de Salud Carlos III · ESVall d'Hebron Hospital Universitari · ESVall d'Hebron Institut de Recerca · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA).

methodsPatients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained.

resultsMean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR).

conclusionMapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.

Indexed as

Aorta, ThoracicAortic DiseasesContrast MediaImaging, Three-DimensionalMagnetic Resonance AngiographyObserver VariationPredictive Value of TestsAdultAgedCardiac-Gated Imaging TechniquesFemaleHumansImage Interpretation, Computer-AssistedMaleMiddle AgedReproducibility of ResultsContrast MediaAortic aneurysmAortic dilationAortic growth rateComputer-assisted image processingMagnetic Resonance Angiography

Identifiers

PMID38211655
PMCPMC11211222
OpenAlexW4390792424

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.