Evidence map›Paper›PMID 38205096›Full record

ArticleAnnals of surgical treatment and research2024

Training efficacy of robotic duct-to-mucosa pancreaticojejunostomy simulation using silicone models for surgical fellows.

Mirang Lee, Youngmin Han, Jae Seung Kang, Yoo Jin Choi, Hee Ju Sohn, Wooil Kwon, Jin-Young Jang

Erratum issuedOpen access · diamondAbstract read
In one paragraph

Article in Annals of surgical treatment and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Observational
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Mirang LeeDepartment of Surgery and Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-3171-2540
Youngmin HanDepartment of Surgery and Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0003-0456-7824
Jae Seung KangDepartment of Surgery and Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-6587-9579
Yoo Jin ChoiDepartment of Surgery and Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-1142-1842
Hee Ju SohnDepartment of Surgery and Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-9339-930X
Wooil KwonDepartment of Surgery and Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-4827-7805
Jin-Young JangDepartment of Surgery and Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0003-3312-0503
Seoul National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: In the era of minimally invasive surgery (MIS), robotic pancreatoduodenectomy (PD) is actively performed, and clinical fellows need to thoroughly prepare for MIS-PD during the training process. Although pancreaticojejunostomy (PJ) is a difficult anastomosis that requires repeated practice, there are obstacles preventing its practice that concerns patient safety and limited time in the actual operating room. This study evaluated the efficacy of simulation-based training of robotic duct-to-mucosa PJ using pancreatic and intestinal silicone models using a scoring system. Methods: Three pancreatobiliary clinical fellows who had never performed a real robotic PJ participated in this study. Each trainee, who was well acquainted with master's video created by a senor surgeon, performed the robotic PJ procedures 9 times, and 3 independent pancreatobiliary surgeons assessed the videos and analyzed the scores using a blind method. Results: The mean robotic PJ times for the 3 trainees were 42.8 and 29.1 minutes for the first and 9th videos, respectively. The mean score was 13.8 (range, 6-17) for the first video and 17.7 (range, 15-19) for the 9th video. When comparing earlier and later attempts, the PJ time decreased significantly (2,201.67 seconds Conclusion: This robotic education system will help pancreatobiliary trainees overcome the learning curves efficiently and quickly without raising ethical concerns associated with animal models or direct practice with human subjects. This will be of practical assistance to trainees preparing for MIS-PD.

Indexed as

PancreaticojejunostomyPhysical education and trainingProfessional educationRoboticsSimulation training

Identifiers

PMID38205096
PMCPMC10774700
OpenAlexW4390649924

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.