Evidence map›Paper›PMID 38204979›Full record

ArticleMethodsX2024

Detection method of viral pneumonia imaging features based on CT scan images in COVID-19 case study.

Fajar Astuti Hermawati, Bambang Riyanto Trilaksono, Anto Satriyo Nugroho, Elly Matul Imah, Lukas, Telly Kamelia, Tati L E R Mengko, Astri Handayani, Stefanus Eric Sugijono, Benny Zulkarnaien and 2 more

Open access · goldAbstract read
In one paragraph

Article in MethodsX, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 6 institutions in 1 country.

Fajar Astuti HermawatiDepartment of Informatics, Universitas 17 Agustus 1945, Surabaya, Indonesia.
Bambang Riyanto TrilaksonoSchool of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia.
Anto Satriyo NugrohoNational Research and Innovation Agency, Indonesia.
Elly Matul ImahData Science Department, Universitas Negeri Surabaya, Indonesia.
LukasElectrial Engineering Department, Universitas Katolik Indonesia Atma Jaya, Jakarta, Indonesia.
Telly KameliaDepartment of Internal Medicine, Dr. Cipto Mangunkusumo National Central Public Hospital, Jakarta, Indonesia.
Tati L E R MengkoSchool of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia.
Astri HandayaniSchool of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia.
Stefanus Eric SugijonoDepartment of Radiology, Eka Hospital Bekasi, Indonesia.
Benny ZulkarnaienDepartment of Radiology, Dr. Cipto Mangunkusumo National Central Public Hospital, Jakarta, Indonesia.
Rahmi AfifiDepartment of Radiology, Dr. Cipto Mangunkusumo National Central Public Hospital, Jakarta, Indonesia.
Dimas Bintang KusumawardhanaSchool of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia.
Bandung Institute of Technology · IDRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo · IDAtma Jaya Catholic University of Indonesia · IDNational Nuclear Energy Agency of Indonesia · IDState University of Semarang · IDUniversitas 17 Agustus 1945 Surabaya · ID

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to automatically analyze and extract abnormalities in the lung field due to Coronavirus Disease 2019 (COVID-19). Types of abnormalities that can be detected are Ground Glass Opacity (GGO) and consolidation. The proposed method can also identify the location of the abnormality in the lung field, that is, the central and peripheral lung area. The location and type of these abnormalities affect the severity and confidence level of a patient suffering from COVID-19. The detection results using the proposed method are compared with the results of manual detection by radiologists. From the experimental results, the proposed system can provide an average error of 0.059 for the severity score and 0.069 for the confidence level. This method has been implemented in a web-based application for general users.•A method to detect the appearance of viral pneumonia imaging features, namely Ground Glass Opacity (GGO) and consolidation on the chest Computed Tomography (CT) scan images.•This method can separate the lung field to the right lung and the left lung, and it also can identify the detected imaging feature's location in the central or peripheral of the lung field.•Severity level and confidence level of the patient's suffering are measured.

Indexed as

ConsolidationGround-Glass-OpacityImage segmentationImage thresholdingMorphological image processing & image thresholdingSeverity level

Identifiers

PMID38204979
PMCPMC10776984
OpenAlexW4389950122

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked