Evidence map›Paper›PMID 38204910›Full record

ArticlePhysics and imaging in radiation oncology2024

Multi-institutional generalizability of a plan complexity machine learning model for predicting pre-treatment quality assurance results in radiotherapy.

Michaël Claessens, Geert De Kerf, Verdi Vanreusel, Isabelle Mollaert, Victor Hernandez, Jordi Saez, Núria Jornet, Dirk Verellen

Open access · goldAbstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Michaël ClaessensDepartment of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium.
Geert De KerfDepartment of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium.
Verdi VanreuselDepartment of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium.
Isabelle MollaertDepartment of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium.
Victor HernandezDepartment of Medical Physics, Hospital Sant Joan de Reus, IISPV, 43204 Tarragona, Spain.
Jordi SaezDepartment of Radiation Oncology, Hospital Clínic de Barcelona, 08036 Barcelona, Spain.
Núria JornetServei de Radiofísica i Radioprotecció, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.
Dirk VerellenDepartment of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium.
University of Antwerp · BEIridium Kankernetwerk · BEHospital Clínic de Barcelona · ESHospital de Sant Pau · ESInstitut de Recerca Biomèdica Catalunya Sud · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Treatment plans in radiotherapy are subject to measurement-based pre-treatment verifications. In this study, plan complexity metrics (PCMs) were calculated per beam and used as input features to develop a predictive model. The aim of this study was to determine the robustness against differences in machine type and institutional-specific quality assurance (QA). Material and methods: A number of 567 beams were collected, where 477 passed and 90 failed the pre-treatment QA. Treatment plans of different anatomical regions were included. One type of linear accelerator was represented. For all beams, 16 PCMs were calculated. A random forest classifier was trained to distinct between acceptable and non-acceptable beams. The model was validated on other datasets to investigate its robustness. Firstly, plans for another machine type from the same institution were evaluated. Secondly, an inter-institutional validation was conducted on three datasets from different centres with their associated QA. Results: Intra-institutionally, the PCMs beam modulation, mean MLC gap, Q1 gap, and Modulation Complexity Score were the most informative to detect failing beams. Eighty-tree percent of the failed beams (15/18) were detected correctly. The model could not detect over-modulated beams of another machine type. Inter-institutionally, the model performance reached higher accuracy for centres with comparable equipment both for treatment and QA as the local institute. Conclusions: The study demonstrates that the robustness decreases when major differences appear in the QA platform or in planning strategies, but that it is feasible to extrapolate institutional-specific trained models between centres with similar clinical practice. Predictive models should be developed for each machine type.

Indexed as

Machine learningMulti-institutional validationPlan complexityQuality assuranceRadiation therapyVMAT

Identifiers

PMID38204910
PMCPMC10776441
OpenAlexW4389955417

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.