Evidence map›Paper›PMID 38203117›Full record

ArticleSensors (Basel, Switzerland)2024

Design, Analysis, and Development of Low-Cost State-of-the-Art Magnetorheological-Based Microprocessor Prosthetic Knee.

Muhammad Usman Qadir, Izhar Ul Haq, Muhammad Awais Khan, Kamran Shah, Houssam Chouikhi, Mohamed A Ismail

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Muhammad Usman QadirAdvanced Robotics & Automation Lab, Department of Mechatronics Engineering, University of Engineering & Technology, Peshawar 25000, Pakistan.
Izhar Ul HaqAdvanced Robotics & Automation Lab, Department of Mechatronics Engineering, University of Engineering & Technology, Peshawar 25000, Pakistan.
Muhammad Awais KhanAdvanced Robotics & Automation Lab, Department of Mechatronics Engineering, University of Engineering & Technology, Peshawar 25000, Pakistan.
Kamran ShahAdvanced Robotics & Automation Lab, Department of Mechatronics Engineering, University of Engineering & Technology, Peshawar 25000, Pakistan.ORCID 0000-0001-5153-1926
Houssam ChouikhiDepartment of Mechanical Engineering, King Faisal University, Hofuf Al Ahsa 31982, Saudi Arabia.ORCID 0000-0002-0470-0771
Mohamed A IsmailDepartment of Mechanical Engineering, King Faisal University, Hofuf Al Ahsa 31982, Saudi Arabia.ORCID 0000-0003-4078-288X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

For amputees, amputation is a devastating experience. Transfemoral amputees require an artificial lower limb prosthesis as a replacement for regaining their gait functions after amputation. Microprocessor-based transfemoral prosthesis has gained significant importance in the last two decades for the rehabilitation of lower limb amputees by assisting them in performing activities of daily living. Commercially available microprocessor-based knee joints have the needed features but are costly, making them beyond the reach of most amputees. The excessive cost of these devices can be attributed to custom sensing and actuating mechanisms, which require significant development cost, making them beyond the reach of most amputees. This research contributes to developing a cost-effective microprocessor-based transfemoral prosthesis by integrating off-the-shelf sensing and actuating mechanisms. Accordingly, a three-level control architecture consisting of top, middle, and low-level controllers was developed for the proposed prosthesis. The top-level controller is responsible for identifying the amputee intent and mode of activity. The mid-level controller determines distinct phases in the activity mode, and the low-level controller was designed to modulate the damping across distinct phases. The developed prosthesis was evaluated on unilateral transfemoral amputees. Since off-the-shelf sensors and actuators are used in i-Inspire, various trials were conducted to evaluate the repeatability of the sensory data. Accordingly, the mean coefficients of correlation for knee angle, force, and inclination were computed at slow and medium walking speeds. The obtained values were, respectively, 0.982 and 0.946 for knee angle, 0.942 and 0.928 for knee force, and 0.825 and 0.758 for knee inclination. These results confirmed that the data are highly correlated with minimum covariance. Accordingly, the sensors provide reliable and repeatable data to the controller for mode detection and intent recognition. Furthermore, the knee angles at self-selected walking speeds were recorded, and it was observed that the i-Inspire Knee maintains a maximum flexion angle between 50° and 60°, which is in accordance with state-of-the-art microprocessor-based transfemoral prosthesis.

Indexed as

Activities of Daily LivingKnee JointAmputation, SurgicalHumansLower ExtremityMicrocomputershierarchical control architecturemagnetorheological dampersemi-active prosthetic kneetransfemoral amputationvariable current controller

Identifiers

PMID38203117
PMCPMC10781202