Evidence map›Paper›PMID 38202984›Full record

ArticleSensors (Basel, Switzerland)2023

Design and Analysis of a Cardioid Flow Tube Valveless Piezoelectric Pump for Medical Applications.

Jialong Wang, Fan Zhang, Zhenzhen Gui, Yuxin Wen, Yaohua Zeng, Tang Xie, Tian Tan, Bochuan Chen, Jianhui Zhang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jialong WangSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Fan ZhangSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Zhenzhen GuiSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.ORCID 0000-0002-4181-1681
Yuxin WenSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Yaohua ZengSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Tang XieSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Tian TanSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Bochuan ChenSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Jianhui ZhangSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.

Funding

On campus research projects at Guangzhou University ZH2023002R&D Program of Joint Institute of GZHU & ICoST GI202108 and GI202110Science and Technology Planning Project of Guangzhou City 2023A03J0120Science and Technology Program of Guangzhou 202201020158The Graduate-Ability-Promotion Plan of Guangzhou University 2022GDJC-M21
6 · The paper itself

Abstract

Piezoelectric pumps play an important role in modern medical technology. To improve the flow rate of valveless piezoelectric pumps with flow tube structures and promote the miniaturization and integration of their designs, a cardioid flow tube valveless piezoelectric pump (CFTVPP) is proposed in this study. The symmetric dual-bend tube design of CFTVPP holds great potential in applications such as fluid mixing and heat dissipation systems. The structure and working principle of the CFTVPP are analyzed, and flow resistance and velocity equations are established. Furthermore, the flow characteristics of the cardioid flow tube (CFT) are investigated through computational fluid dynamics, and the output performance of valveless piezoelectric pumps with different bend radii is studied. Experimental results demonstrate that CFTVPP exhibits the pumping effect, with a maximum vibration amplitude of 182.5 μm (at 22 Hz, 100 V) and a maximum output flow rate of 5.69 mL/min (at 25 Hz, 100 V). The results indicate that a smaller bend radius of the converging bend leads to a higher output flow rate, while the performance of valveless piezoelectric pumps with different diverging bends shows insignificant differences. The CFTVPP offers advantages such as a high output flow rate, low cost, small size for easy integration, and ease of manufacturing.

Indexed as

cardioid tubeCFD simulationpiezoelectric pumpsecondary flowvalveless

Identifiers

PMID38202984
PMCPMC10781215

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.