ReviewJournal of clinical medicine2023
New Horizons of Cementless Total Knee Arthroplasty.
Review in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Returning to running after total knee arthroplasty: a systematic review and a novel multimodal protocol.Musculoskeletal surgery · 2025Pooled it
- Long-Term Clinical and Radiological Outcomes of Cementless Total Knee Arthroplasty in Patients with Rheumatoid Arthritis.Journal of clinical medicine · 2026Article
- Ninety-day readmission and early complications after coding-defined cementless-category versus cemented-category primary total knee arthroplasty.Arthroplasty (London, England) · 2026Article
- Frictional behavior between bone and additively manufactured Ti6Al4V implants is affected by bone density and surface texture under varying loads.Scientific reports · 2025Article
- Cementless vs. Cemented Total Knee Arthroplasty: Reduced Operative Time with Comparable Perioperative Safety-A Retrospective Cohort from a Tertiary Care Center.Journal of clinical medicine · 2025Article
- Similar clinical and survival outcomes between robotic-assisted cemented and cementless total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2025Article
- Novel Clinical Applications of 3D-Printed Highly Porous Titanium for Off-the-Shelf Cementless Joint Replacement Prostheses.Biomimetics (Basel, Switzerland) · 2025Article
- Global trends in fixation methods for primary total knee arthroplasty: An international registry-based analysis and review of outcomes.Journal of orthopaedics · 2025Article
- Fixation in total knee arthroplasty: are cemented implants still mandatory in younger and obese patients?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Review
- Long-Term Outcomes of Cementless Versus Hybrid Cemented Total Knee Arthroplasty: A Minimum 10-Year Follow-Up.Journal of clinical medicine · 2025Article
- Clinical outcomes and radiolucent line analysis in cementless mobile-bearing total knee arthroplasty: a prospective multicentre study in Japan.Scientific reports · 2024Article
- Laser Bone Shaping: Current Capabilities and Future Applications in Knee Arthroplasty.JB & JS open accessReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundConsidering the increasing number of young and active patients needing TKA, orthopedic surgeons are looking for a long-lasting and physiological bond for the prosthetic implant. Multiple advantages have been associated with cementless fixation including higher preservation of the native bone stock, avoidance of cement debris with subsequent potential third-body wear, and the achievement of a natural bond and osseointegration between the implant and the bone that will provide a durable and stable fixation. DISCUSSION: Innovations in technology and design have helped modern cementless TKA implants to improve dramatically. Better coefficient of friction and reduced Young's modulus mismatch between the implant and host bone have been related to the use of porous metal surfaces. Moreover, biologically active coatings have been used on modern implants such as periapatite and hydroxyapatite. These factors have increased the potential for ingrowth by reducing micromotion and increasing osteoconductive properties. New materials with better biocompatibility, porosity, and roughness have been introduced to increase implant stability.
conclusionsInnovations in technology and design have helped modern cementless TKA implants improve primary stability in both the femur and tibia. This means that short-term follow-up are comparable to cemented. These positive prognostic factors may lead to a future in which cementless fixation may be considered the gold-standard technique in young and active patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials