Stabilization of Traumatic Iliosacral Instability Using Innovative Implants: A Biomechanical Comparison.

Niklas Grüneweller, Julia Leunig, Ivan Zderic, Boyko Gueorguiev, Dirk Wähnert, Thomas Vordemvenne

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Percutaneous fixation of posterior pelvic ring lesions in the elderly: current evidence and recent advances.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Niklas GrünewellerBielefeld University, Medical School and University Medical Center OWL, Protestant Hospital of the Bethel Foundation, Department of Trauma and Orthopedic Surgery, Burgsteig 13, 33617 Bielefeld, Germany.
Julia LeunigAO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland.
Ivan ZdericAO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland.ORCID 0000-0003-0484-887X
Boyko GueorguievAO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland.ORCID 0000-0001-9795-115X
Dirk WähnertBielefeld University, Medical School and University Medical Center OWL, Protestant Hospital of the Bethel Foundation, Department of Trauma and Orthopedic Surgery, Burgsteig 13, 33617 Bielefeld, Germany.ORCID 0000-0002-2352-7951
Thomas VordemvenneBielefeld University, Medical School and University Medical Center OWL, Protestant Hospital of the Bethel Foundation, Department of Trauma and Orthopedic Surgery, Burgsteig 13, 33617 Bielefeld, Germany.
AO Foundation · CHBielefeld University · DE

Funding

Silony Medical (Switzerland) Biomech_TriFix
6 · The paper itself

Abstract

(1) Background: Demographic changes over the past decade have had a significant impact on pelvic ring fractures. They have increased dramatically in the orthogeriatric population. Surgeons are faced with implant fixation issues in the treatment of these fragility fractures. This study compares two innovative implants for stabilizing the iliosacral joint in a biomechanical setting. (2) Methods: An iliosacral screw with a preassembled plate allowing the placement of an additional short, angular stable screw in the ilium and a triangular fixation system consisting of a fenestrated ilium screw and an iliosacral screw quasi-statically inserted through the "fenestra" were instrumented in osteoporotic artificial bone models with a simulated Denis zone 1 fracture. Biomechanical testing was performed on a servo-hydraulic testing machine using increasing, synchronous axial and torsional sinusoidal cyclic loading to failure. (3) Results: The SI-Plate and TriFix showed comparable stiffness values. The values for fracture gap angle and screw tip cutout were significantly lower for the TriFix compared to the SI-Plate. In addition, the number of cycles to failure was significantly higher for the TriFix. (4) Conclusions: Implant anchorage and primary stability can be improved in iliosacral instability using the triangular stabilization system.

Indexed as

biomechanicdorsal pelvic ringiliosacral instabilitySI-platetriangular fixation