Evidence map›Paper›PMID 38196822›Full record

ArticleIEEE journal of translational engineering in health and medicine2024

Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor.

Sheik Mohammed Ali, Sridhar Poosapadi Arjunan, James Peter, Laura Perju-Dumbrava, Catherine Ding, Michael Eller, Sanjay Raghav, Peter Kempster, Mohammod Abdul Motin, P J Radcliffe and 1 more

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Sheik Mohammed AliDepartment of Electrical and Biomedical EngineeringRMIT University Melbourne VIC 3000 Australia.
Sridhar Poosapadi ArjunanSRM Institute of Science and Technology Chennai 603203 India.ORCID 0000-0002-7288-0380
James PeterNeurosciences DepartmentMonash Health Clayton VIC 3168 Australia.
Laura Perju-DumbravaNeurosciences DepartmentMonash Health Clayton VIC 3168 Australia.
Catherine DingNeurosciences DepartmentMonash Health Clayton VIC 3168 Australia.
Michael EllerNeurosciences DepartmentMonash Health Clayton VIC 3168 Australia.
Sanjay RaghavDepartment of Electrical and Biomedical EngineeringRMIT University Melbourne VIC 3000 Australia.
Peter KempsterNeurosciences DepartmentMonash Health Clayton VIC 3168 Australia.ORCID 0000-0002-6321-3930
Mohammod Abdul MotinDepartment of Electrical and Biomedical EngineeringRMIT University Melbourne VIC 3000 Australia.ORCID 0000-0003-1618-3772
P J RadcliffeDepartment of Electrical and Biomedical EngineeringRMIT University Melbourne VIC 3000 Australia.
Dinesh Kant KumarDepartment of Electrical and Biomedical EngineeringRMIT University Melbourne VIC 3000 Australia.ORCID 0000-0003-3602-4023

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSeveral validated clinical scales measure the severity of essential tremor (ET). Their assessments are subjective and can depend on familiarity and training with scoring systems.

methodWe propose a multi-modal sensing using a wearable inertial measurement unit for estimating scores on the Fahn-Tolosa-Marin tremor rating scale (FTM) and determine the classification accuracy within the tremor type. 17 ET participants and 18 healthy controls were recruited for the study. Two movement disorder neurologists who were blinded to prior clinical information viewed video recordings and scored the FTM. Participants drew a guided Archimedes spiral while wearing an inertial measurement unit placed at the mid-point between the lateral epicondyle of the humerus and the anatomical snuff box. Acceleration and gyroscope recordings were analyzed. The ratio of the power spectral density between frequency bands 0.5-4 Hz and 4-12 Hz, and the sum of power spectrum density over the entire spectrum of 2-74 Hz, for both accelerometer and gyroscope data, were computed. FTM was estimated using regression model and classification using SVM was validated using the leave-one-out method.

resultsRegression analysis showed a moderate to good correlation when individual features were used, while correlation was high ([Formula: see text] = 0.818) when suitable features of the gyro and accelerometer were combined. The accuracy for two-class classification of the combined features using SVM was 91.42% while for four-class it was 68.57%.

conclusionPotential applications of this novel wearable sensing method using a wearable Inertial Measurement Unit (IMU) include monitoring of ET and clinical trials of new treatments for the disorder.

Indexed as

Essential TremorWearable Electronic DevicesAccelerationAccelerometryHumansTremorEssential tremorFahn-Tolosa-Marin tremor rating scaleinertial measurement unitwearables

Identifiers

PMID38196822
PMCPMC10776092

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.