Evidence map›Paper›PMID 38195665›Full record

ArticleScientific reports2024

Performance of textured dual mobility total hip prosthesis with a concave dimple during Muslim prayer movements.

M Muchammad, Mohammad Tauviqirrahman, Muhammad Imam Ammarullah, Muhammad Iqbal, Budi Setiyana, J Jamari

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
10.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 18 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 3 countries.

M MuchammadLaboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Universitas Diponegoro, Semarang, 50275, Central Java, Indonesia. muchammad@lecturer.undip.ac.id.ORCID 0000-0002-9999-1574
Mohammad TauviqirrahmanLaboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Universitas Diponegoro, Semarang, 50275, Central Java, Indonesia.ORCID 0000-0003-2694-4184
Muhammad Imam AmmarullahLaboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Universitas Diponegoro, Semarang, 50275, Central Java, Indonesia.ORCID 0000-0002-8845-7202
Muhammad IqbalLaboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Universitas Diponegoro, Semarang, 50275, Central Java, Indonesia.
Budi SetiyanaLaboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Universitas Diponegoro, Semarang, 50275, Central Java, Indonesia.ORCID 0000-0003-1498-0735
J JamariLaboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Universitas Diponegoro, Semarang, 50275, Central Java, Indonesia.ORCID 0000-0002-6172-2635
Diponegoro University · ID

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The single mobility bearing as a previous bearing design of total hip prosthesis has severe mobility constraints that can result in dislocation during Muslim (people who follow the Islam as religion) prayer movements, specifically shalat that requires intense movement. There are five intense movements (i.e., bowing, prostration, sitting, transition from standing to prostration, and final sitting) during Muslim prayer that may generate an impingement problem for patients with total hip prosthesis. In this work, textured dual mobility total hip prosthesis with two textured cases (i.e., textured femoral head and textured inner liner) are presented and their performances are numerically evaluated against untextured surface model during Muslim prayer movement. The concave dimple design is chosen for surface texturing, while for simulating femoral head materials, SS 316L and CoCrMo is choosen. To represent the real condition, three-dimensional computational fluid dynamics (CFD) coupled with two-way fluid-structure interaction (FSI) methods are employed to analyze elastohydrodynamic lubrication problem with non-Newtonian synovial fluid model. The main aim of the present study is to investigate the tribological performance on dual mobility total hip prosthesis with applied textured surface with concave dimple in femoral head and inner liner surface under Muslim prayer movements. It is found that applying surface texturing has a beneficial effect on the lubrication performance for some intense movements. The textured femoral head model performs better than textured inner liner model and untextured model (both femoral head and inner liner). The numerical results also indicate superior performance of CoCrMo femoral head compared to SS 316L femoral head. These findings can be used as a reference for biomedical engineers and orthopedic surgeons in designing and choosing suitable total hip prosthesis for Muslims makes they can carry out Muslim prayer movements like humans in general who have normal hip joints.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisBiomedical EngineeringHip JointHumansIslam

Identifiers

PMID38195665
PMCPMC10776789
OpenAlexW4390781046

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.