Evidence map›Paper›PMID 38192890›Full record

ArticleAdvanced biomedical research2023

Clinical Outcomes of Double Mini-Plating Compared with a Single Superior Plating in Midshaft Clavicular Fractures: A Randomized Clinical Trial Study.

Meisam Jafari Kafiabadi, Amir Sabaghzadeh, Saber Barazandeh Rad, Amin Karami, Mehrdad Sadighi, Farsad Biglari

Open access · goldAbstract read
In one paragraph

Article in Advanced biomedical research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Augmentation of clavicular fractures by dual plating.International journal of burns and trauma · 2025
    Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Meisam Jafari KafiabadiDepartment of Orthopedic Surgery, Clinical Research Development Unit of Shohada-e Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Amir SabaghzadehDepartment of Orthopedic Surgery, Clinical Research Development Unit of Shohada-e Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Saber Barazandeh RadDepartment of Orthopedic Surgery, Clinical Research Development Unit of Shohada-e Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Amin KaramiDepartment of Orthopedic Surgery, Clinical Research Development Unit of Shohada-e Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Mehrdad SadighiDepartment of Orthopedic Surgery, Clinical Research Development Unit of Shohada-e Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Farsad BiglariDepartment of Orthopedic Surgery, Clinical Research Development Unit of Shohada-e Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Shahid Beheshti University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In the current study, we aimed to assess the clinical outcomes of the double-plating method using 2.7 mm compression plates compared with the single superior 3.5 mm compression plating method in displaced midshaft fractures of the clavicle. Materials and Methods: Thirty patients with midshaft fractures of the clavicle were randomly assigned into two groups. In group A, 15 patients were fixed by a double-plating technique using two 2.7 mm compression plates on the superior and anteroinferior sides of the bone. The fractures in group B were fixed by a superior plating technique using a single 3.5 mm compression plate. Intraoperative bleeding measurement, length of surgical incision, duration of procedure time, and functional scores were assessed post-surgically through one-year follow-ups. Results: There was no significant difference between groups in terms of surgery time. Device failure was not found among all recruited patients. Incision length and device prominence complaint were significantly different between groups ( Conclusion: Double mini-plating of diaphyseal clavicular fractures could result in a smaller surgical incision and a lower rate of prominence without affecting fixation stability and clinical outcomes in comparison with single superior 3.5 mm plates.

Indexed as

Claviclefractureplating

Identifiers

PMID38192890
PMCPMC10772796
OpenAlexW4390706591

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.