Evidence map›Paper›PMID 38187934›Full record

ArticleJournal of biomedical optics2024

Large-field-of-view optical-resolution optoacoustic microscopy using a stationary silicon-photonics acoustic detector.

Tamar Harary, Michael Nagli, Nathan Suleymanov, Ilya Goykhman, Amir Rosenthal

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Photoacoustics · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Tamar HararyTechnion - Israel Institute of Technology, The Andrew and Erna Viterbi Faculty of Electrical and Computer Engineering, Haifa, Israel.
Michael NagliTechnion - Israel Institute of Technology, The Andrew and Erna Viterbi Faculty of Electrical and Computer Engineering, Haifa, Israel.
Nathan SuleymanovTechnion - Israel Institute of Technology, The Andrew and Erna Viterbi Faculty of Electrical and Computer Engineering, Haifa, Israel.
Ilya GoykhmanTechnion - Israel Institute of Technology, The Andrew and Erna Viterbi Faculty of Electrical and Computer Engineering, Haifa, Israel.
Amir RosenthalTechnion - Israel Institute of Technology, The Andrew and Erna Viterbi Faculty of Electrical and Computer Engineering, Haifa, Israel.
Technion – Israel Institute of Technology · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: Optical-resolution optoacoustic microscopy (OR-OAM) enables label-free imaging of the microvasculature by using optical pulse excitation and acoustic detection, commonly performed by a focused optical beam and an ultrasound transducer. One of the main challenges of OR-OAM is the need to combine the excitation and detection in a coaxial configuration, often leading to a bulky setup that requires physically scanning the ultrasound transducer to achieve a large field of view. Aim: The aim of this work is to develop an OR-OAM configuration that does not require physically scanning the ultrasound transducer or the acoustic beam path. Approach: Our OR-OAM system is based on a non-coaxial configuration in which the detection is performed by a silicon-photonics acoustic detector (SPADE) with a semi-isotropic sensitivity. The system is demonstrated in both epi- and trans-illumination configurations, where in both configurations SPADE remains stationary during the imaging procedure and only the optical excitation beam is scanned. Results: The system is showcased for imaging resolution targets and for the Conclusions: We showcase a new OR-OAM design, compatible with epi-illumination configuration. This setup enables relatively large fields of view without scanning the acoustic detector or acoustic beam path. Furthermore, it offers the potential for high-speed imaging within compact, miniature probe and could potentially facilitate the clinical translation of OR-OAM technology.

Indexed as

MicroscopySiliconAcousticsAnimalsHeart RateLightingMiceSiliconimaging techniquesmicro-ring silicon-photonics acoustic detectoroptical-resolution optoacoustic microscopyphotoacoustic imagingsilicon-photonics acoustic detector

Identifiers

PMID38187934
PMCPMC10768684
OpenAlexW4390689705

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.