Evidence map›Paper›PMID 38187293›Full record

ArticleHeliyon2024

Diagnosis of atrial fibrillation based on AI-detected anomalies of ECG segments.

Sanghoon Choi, Kyungmin Choi, Hong Kyun Yun, Su Hyeon Kim, Hyeon-Hwa Choi, Yi-Seul Park, Segyeong Joo

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.5field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Sanghoon ChoiDepartment of Biomedical Engineering, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Kyungmin ChoiDepartment of Biomedical Engineering, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Hong Kyun YunDepartment of Biomedical Engineering, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Su Hyeon KimDepartment of Biomedical Engineering, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Hyeon-Hwa ChoiDepartment of Biomedical Engineering, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Yi-Seul ParkDepartment of Biomedical Engineering, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Segyeong JooDepartment of Biomedical Engineering, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Ulsan College · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Early detection of atrial fibrillation (AF) is crucial for its effective management and prevention. Various methods for detecting AF using deep learning (DL) based on supervised learning with a large labeled dataset have a remarkable performance. However, supervised learning has several problems, as it is time-consuming for labeling and has a data dependency problem. Moreover, most of the DL methods do not provide any clinical evidence to physicians regarding the analysis of electrocardiography (ECG) for classification or detection of AF. To address these limitations, in this study, we proposed a novel AF diagnosis system using unsupervised learning for anomaly detection with three segments, PreQ, QRS, and PostS, based on the normal ECG. Two independent datasets, PTB-XL and China, were used in three experiments. We used a long short-term memory (LSTM)-based autoencoder to train the segments of the normal ECG. Based on the threshold of anomaly scores using mean squared error (MSE), it distinguished between normal and AF segments. In Experiment A, the best score was that of PreQ, which detected AF with an AUROC score of 0.96. In Experiment B and C for cross validation of each dataset, the best scores were also of PreQ, with AUROC scores of 0.9 and 0.95, respectively. To verify the significance of the anomaly score in distinguishing between AF and normal segments, we utilized an XG-Boosted model after generating anomaly scores in the three segments. The XG-Boosted model achieved an AUROC score of 0.98 and an F1 score of 0.94. AF detection using DL has been controversial among many physicians. However, our study differentiates itself from previous studies in that we can demonstrate evidence that distinguishes AF from normal segments based on the anomaly score.

Indexed as

Anomaly detectionAtrial fibrillationAutoencoderClinical evidenceElectrocardiogram

Identifiers

PMID38187293
PMCPMC10770559
OpenAlexW4389628021

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.