ArticleHardwareX2023
A low-cost, portable 32-channel EIT system with four rings based on AFE4300 for body composition analysis.
Article in HardwareX, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- A portable, low-cost, and open-source electrical impedance tomography system with a modular analog front-end based on STM32 and AD5933.HardwareX · 2026Article
- Eight-channel high-speed electrical impedance tomography device implemented on a programmable system on a chip.HardwareX · 2025Review
- A Wearable Open-Source electrical impedance tomography device.HardwareX · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A proposed low-cost, portable, 32-channel (4 rings of 8-channel) Electrical Impedance Tomography (EIT) system based on the AFE4300 analog front-end for body composition measurement. Each ring allows obtaining the conductivity distribution of 4 cross sections, 4 cm apart; to analyze the behavior of conductivity in a volume. The switching of the 4 rings and the current injection and voltage measurement patterns are done with three Texas Instruments 74HC4067 multiplexers, which are managed by an ESP32 board. The proposed system has an average signal-to-noise ratio of 74.71 dB and a frame rate of 50 fps. The sensitivity tests to impedance and volume changes consisted of introducing 4 tubes of different diameters (2 steel and 2 polyvinyl chloride) into a tank with saline solution; then conductivity distribution images were generated in 4 cross-sections of the tank, using the algorithms Gauss-Newton and Noser. Finally, the global impedance index (GI) is calculated to estimate the volume of each tube inside the tank. The results show that the proposed system is highly sensitive to impedance and volume changes, being a promising system for monitoring tissues, and fluids biological.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.