ReviewAdvances in therapy2024
Comparative Safety of Pulsed Field Ablation and Cryoballoon Ablation Technologies for Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation: A Critical Literature Review and Indirect Treatment Comparison.
Review in Advances in therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Comparison of HEMOlysis Markers Among Three Pulsed Field Ablation Systems: HEMO-PFA Study.Journal of cardiovascular electrophysiology · 2026Article
- Pulsed-field ablation versus cryoballoon ablation in patients with atrial fibrillation: A systematic review, meta-analysis and meta-regression.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026Review
- Pulsed-field ablation versus cryoballoon ablation in patients with atrial fibrillation: A systematic review, meta-analysis and meta-regression.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026Review
- Comparative efficacy and safety of pulsed field ablation versus cryoballoon ablation in atrial fibrillation: A meta-analysis of mid- and long-term outcomes.International journal of cardiology. Heart & vasculature · 2026Review
- Inflammatory and Myocardial Biomarker Response Following Pulmonary Vein Isolation: Cryoballoon Versus Balloon-in-Basket Pulsed Field Ablation.Journal of cardiovascular electrophysiology · 2026Article
- Severe Esophageal Complications Following Atrial Fibrillation Ablation: Should We Still Be Concerned?Arquivos brasileiros de cardiologia · 2025Review
- Impact of venous closure systems on time to ambulation and discharge following AF ablation: a systematic review and meta-analytic review.The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionCryoballoon ablation (CBA) is a standard catheter ablation technology with demonstrated clinical effectiveness for the treatment of paroxysmal atrial fibrillation (PAF); however, it can be associated with major adverse events, including phrenic nerve paralysis. Pulsed field ablation (PFA) is a novel, minimally thermal technology with comparable effectiveness and low safety risk. This study aimed to compare the safety profiles of PFA and CBA through critical analyses of the literature and indirect treatment comparisons.
methodsStudies were identified by searching the MEDLINE database and the Clinicaltrials.gov registry. Registered clinical trials and/or Food and Drug Administration Investigation Device Exemption (FDA IDE) studies evaluating PFA or CBA in adult patients with drug-refractory PAF between January 2008 and March 2023 were selected. Comparative safety between PFA and CBA was assessed for major and prespecified adverse events. Indirect comparisons were conducted using the proportion of patients experiencing adverse events and confirmed with single-arm meta-analyses and sensitivity analyses.
resultsData were extracted from three PFA publications including a total of 497 patients and six CBA studies including a total of 1113 patients. The analysis revealed that PFA was associated with significantly lower risk of major adverse events {risk difference - 4.3% [95% confidence interval (CI) - 5.8, - 2.8]; risk ratio 0.16 [95% CI 0.07, 0.45]} and prespecified adverse events [risk difference - 2.5% (95% CI - 4.4, - 0.5); risk ratio 0.53 (95% CI 0.31, 0.96)]. Meta-analyses confirmed the lower rate of major adverse events for PFA [0.4% (95% CI 0.0, 1.3)] vs. CBA [5.6% (95% CI 2.6, 8.6)] and prespecified adverse events for PFA [2.7% (95% CI 1.2, 4.1)] vs. CBA [5.8% (95% CI 2.7, 9.0)]. Sensitivity analyses exploring heterogeneity across studies confirmed robustness of the main analyses.
conclusionThe findings of this study show that PFA has a more favorable safety profile than CBA, with significantly lower risks of major and prespecified adverse events. These indirect comparisons help contextualize the safety of PFA compared to CBA for the treatment of drug-refractory PAF in the absence of head-to-head studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.