Evidence map›Paper›PMID 38184698›Full record

ArticleScientific reports2024

A proof of concept study on reliability assessment of different metal foil length based piezoelectric sensor for electromechanical impedance techniques.

Lukesh Parida, Sumedha Moharana, Romeu Vicente, Guilherme Ascensão

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Lukesh ParidaDepartment of Civil Engineering, Shiv Nadar Institution of Eminence, Dadri, Uttar Pradesh, 201314, India.ORCID http://orcid.org/0000-0001-9654-8019
Sumedha MoharanaDepartment of Civil Engineering, Shiv Nadar Institution of Eminence, Dadri, Uttar Pradesh, 201314, India. sumedha.maharana@snu.edu.in.ORCID http://orcid.org/0000-0001-9924-5283
Romeu VicenteRISCO, Department of Civil Engineering, University of Aveiro, 3810-193, Aveiro, Portugal.ORCID http://orcid.org/0000-0002-5456-1642
Guilherme AscensãoRISCO, Department of Civil Engineering, University of Aveiro, 3810-193, Aveiro, Portugal. guilhermeascensao@ua.pt.ORCID http://orcid.org/0000-0002-6003-4486

Funding

Fundação para a Ciência e a Tecnologia FCT/UIDB/ECI/04450/2020
6 · The paper itself

Abstract

Lead zirconate titanate (PZT) patches gained popularity in structural health monitoring (SHM) for its sensing and cost effective. However, a robust installation of PZT patches is challenging due to the often-complex geometry and non-accessibility of structural parts. For tubular structures, the curved surface can compromise the perfect bonding of PZT patches. To alleviate the above-mentioned challenges, the non-bonded and reusable configuration of sensor received considerable interest in the field of SHM. However, ensuring the repeatability and reproducibility of Electro-Mechanical Impedance (EMI) measurements is crucial to establish the reliability of these techniques. This work investigated the repeatability and reproducibility measures for one of non-bonded configuration of PZT patch i.e., Metal Foil Based Piezo Sensor (MFBPS). In addition, the concept, application, and suitability of MFBPS for impedance-based monitoring technique of Civil infrastructure are critically discussed. This study evaluates the effect of length of MFBPS on piezo coupled admittance signature. Also, this study evaluates repeatability and reproducibility of EMI measurements via statistical tools such as ANOVA and Gage R&R analysis. The statistical index CCDM was used to quantify the deviations of impedance signals. The overall result shows that the repeatability of the EMI measurements improves with a metal foil length of 500 mm. Overall, this investigation offers a useful point of reference for professionals and scholars to ensure the reliability of MFBPS for EMI techniques, a variant of piezoelectric sensor for SHM applications.

Identifiers

PMID38184698
PMCPMC10771417

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.