Evidence map›Paper›PMID 38181655›Full record

ArticleInternational journal of surgery case reports2024

Successful treatment of an anastomotic leakage after total gastrectomy using a fully covered self-expandable metal stent with an anchoring thread: A case report.

Yosuke Egami, Keijiro Sugimura, Toru Masuzawa, Shinnsuke Katsuyama, Yutaka Takeda, Kohei Murata

Open access · goldAbstract readCase Reports
In one paragraph

Article in International journal of surgery case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Yosuke EgamiDepartment of Gastroenterological Surgery, Kansai Rosai Hospital, 3-1-69, Inabaso, Amagasaki city, Hyogo 660-8511, Japan.
Keijiro SugimuraDepartment of Gastroenterological Surgery, Kansai Rosai Hospital, 3-1-69, Inabaso, Amagasaki city, Hyogo 660-8511, Japan. Electronic address: sugimura-keijiro@kansaih.johas.go.jp.
Toru MasuzawaDepartment of Gastroenterological Surgery, Kansai Rosai Hospital, 3-1-69, Inabaso, Amagasaki city, Hyogo 660-8511, Japan.
Shinnsuke KatsuyamaDepartment of Gastroenterological Surgery, Kansai Rosai Hospital, 3-1-69, Inabaso, Amagasaki city, Hyogo 660-8511, Japan.
Yutaka TakedaDepartment of Gastroenterological Surgery, Kansai Rosai Hospital, 3-1-69, Inabaso, Amagasaki city, Hyogo 660-8511, Japan.
Kohei MurataDepartment of Gastroenterological Surgery, Kansai Rosai Hospital, 3-1-69, Inabaso, Amagasaki city, Hyogo 660-8511, Japan.
Kansai Rosai Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

intoroduction and importanceThe incidence of anastomotic leakage in the esophagojejunostomy after total gastrectomy is a serious complication of this procedure. Here, we report a case in which a fully covered stent was endoscopically placed into a fistula caused by anastomotic leakage after total gastrectomy. CASE PRESENTATION: An 88-year-old man diagnosed with advanced gastric cancer had tumor invasion close to the esophagogastric junction. We performed a laparoscopic total gastrectomy and Roux-en-Y reconstruction. On postoperative day (POD) 3, the patient experienced septic shock due to anastomotic leakage and subsequent mediastinitis. Mediastinal irrigation and drainage under laparotomy were performed. Sepsis improved with drainage, but the fistula persisted due to anastomotic leakage. CLINICAL DISCUSSION: Based on a diagnosis of refractory fistula, a fully covered self-expandable metal stent (HANAROSTENT® Esophagus) was inserted POD 21 using esophagoscopy. To prevent stent migration, a 3-0 silk thread was attached to the ostial side of the stent and fixed at the nose. The stent was endoscopically removed 36 days. Esophagoscopy after stent removal revealed that the fistula had resolved and that the anastomotic leakage had healed. The patient started oral intake and was discharged home.

conclusionThis case demonstrates the potential for use of a fully covered self-expandable metal stent with an anchoring thread for anastomotic leakage after total gastrectomy for gastric cancer.

Indexed as

Anastomotic leakageEsophagojejunostomyFully covered self-expandable metal stentGastric cancer

Identifiers

PMID38181655
PMCPMC10809106
OpenAlexW4390577663

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.