Evidence map›Paper›PMID 38180879›Full record

ArticleInterdisciplinary cardiovascular and thoracic surgery2024

Five-year outcomes of surgical aortic valve replacement with a novel bovine pericardial bioprosthesis.

Jinmiao Chen, Minzhi Lv, Jiahui Fu, Chen He, Yingqiang Guo, Liang Tao, Xinmin Zhou, Tianxiang Gu, Krzysztof Bartus, Lai Wei and 2 more

Abstract read
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Jinmiao ChenDepartment of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.ORCID 0000-0003-4326-0665
Minzhi LvDepartment of Biostatistics, Zhongshan Hospital, Fudan University, Shanghai, China.ORCID 0000-0002-7994-2257
Jiahui FuDepartment of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
Chen HeDepartment of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
Yingqiang GuoDepartment of Cardiovascular Surgery, West China Hospital, Sichuan University, Sichuan, China.
Liang TaoDepartment of Cardiovascular Surgery, Wuhan Asia Heart Hospital, Hubei, China.
Xinmin ZhouDepartment of Cardiovascular Surgery, The Second Xiangya Hospital of Central South University, Hunan, China.
Tianxiang GuDepartment of Cardiovascular Surgery, The First Hospital of China Medical University, Liaoning, China.
Krzysztof BartusDepartment of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College, John Paul II Hospital, Krakow, Poland.
Lai WeiDepartment of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
Tao HongDepartment of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
Chunsheng WangDepartment of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.

Funding

National Natural Science Foundation of China 82200526Shanghai Rising-Star Program 23QB1400900
6 · The paper itself

Abstract

objectivesThe short-term performance of the Cingular bovine pericardial aortic valve was proven. This study evaluated its 5-year safety and haemodynamic outcomes.

methodsIt enrolled 148 patients who underwent surgical aortic valve replacement with the Cingular bovine pericardial aortic valve between March 2016 and October 2017 in 5 clinical centres in China. Safety and haemodynamic outcomes were followed up to 5 years. The incidence of all-cause mortality, structural valve deterioration and reintervention was estimated by Kaplan-Meier analysis.

resultsThe mean age of patients was 67.7 [standard deviation (SD) 5.1] years, and 36.5% of patients were female. The mean follow-up was 5.3 (SD 1.2) years. Five-year freedom from all-cause mortality, structural valve deterioration and all-cause reintervention were 91.2%, 100% and 99.3%, respectively. At 5 years, the mean gradient and effective orifice area of all sizes combined were 14.0 (SD 5.5) mmHg and 1.9 (SD 0.3) cm2, respectively. For 19- and 21-mm sizes of aortic prostheses, the mean gradients and effective orifice area at 5 years were 17.5 (SD 7.0) mmHg and 1.6 (SD 0.2) cm2 and 13.7 (SD 6.7) mmHg and 1.8 (SD 0.3) cm2, respectively. The incidence of moderate or severe patient-prosthesis mismatch was 4.1% and 0.0% patients at 5 years, respectively.

conclusionsThe 5-year safety and haemodynamic outcomes of Cingular bovine pericardial aortic valve are encouraging. Longer-term follow-up is warranted to assess its true durability.

Indexed as

Bovine pericardial valveHaemodynamicsSafetySurgical aortic valve replacement

Identifiers

PMID38180879
PMCPMC10781661

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.